Page 190 - Parker - Hydraulic and Lube Filtration Products
P. 190

Guardian Series


               Installation and Specifi cation Data

               Maximum Allowable Operating     Operating Temperatures:         Electrical Motor: ¼ hp@2500 rpm.
               Pressure (MAOP):  50 psi (3.4   Unit:  -15°F to 180°F (-26°C to    24 VDC; 10A max.
               bar)                            82°C)                              110-120 VAC; 50/60 Hz; 3A max.
                                               Wand/Hose:  25°F to 120°F          220-240 VAC; 50/60 Hz; 1.5A max.
               Flow Capacity:  Up to 4 gpm
                                                          (-4°C to 49°C)          Thermal overload protected.
                            (15 lpm)
                                                                                  Replaceable brushes (500 hours).
               Maximum Recommended Fluid       Visual Indicator:  Differential
               Viscosity:  (.85 specifi c gravity)   pressure type, set at 25 psid  Weight: approximately 23 lbs. 5 oz.
               110-120 VAC and                 Recommended Fluids: petroleum   Materials:
                 220-240 VAC      16,000 SUS   based oils, water emulsions, and   Housing:  cast aluminum
               24VDC              11,000 SUS   diesel fuels                       Cover:  die cast aluminum
                                                                                  Handle and Indicator:  nylon
               Warning:  Explosion hazard.  Do   Integral Relief Valve: set at 50 psi
                                                                                  Wands and Hose:  PVC
               not pump fl ammable liquids such   for motor protection.
                                                                                  Fittings:  brass
               as gasoline, alcohol, solvents, etc.  Noise Level: <70db at 3 ft.
                                                                                  Seals:  fl uorocarbon/
                                                                                       carboxylated nitrile


                                                                3 wire (1.5mm 2  cross section)
                                                  18/3 power cord with
              Guardian Schematic                  3 prong plug. 1 ft.  power cord, 3 ft. lenth  Non conductive  139.7  Minimum
                                                  length(110/120 VAC).  (220/240 VAC).  carrying handle.  5.50  Element removal clearance.
                                                              Quick access, zero      25 PSI differential
                                                              leakage, ¾-11.5 NH      visual indicator.
                                                              garden hose connections.

                                  ¾” lightweight                                                     Removable element.
                                  wand assembly,
                                  3 ft. full extended
                                  length.
                                                                                                            208.5
                                                                                                            8.21





                                                                                            Vibration isolating rubber
                                                                                            feet 4-pls.
                                    ¾”wire reinforced fl exible
                                    inlet hose, 5 ft. length.  ¾”wire reinforced fl exible  ¾”- 11.5 NH
                                                  outlet hose, 5 ft. length.  garden hose
                                                                   thread(Outlet).
                      #10-24 Terminal Studs
                      2-places (24 VDC)
                                                     millimeter
                                           Linear Measure:             Motor is UL recognized
                                                        inch
                                                                       and CSA listed
             On/off
             switch

                                                                                                            195
                                                                                                            7.68
                                              Inlet
              50.8
              2.00
                                              Outlet           Clean inlet strainer as required
                                                                             Visible and easily
                            152.4                                            cleanable inlet strainer
                            6.00
                   Alternate customer exchangeable, ½-14 NPT                   398.5
                   inlet and outlet locations (Plugged).                       15.69
                                                             185
   185   186   187   188   189   190   191   192   193   194   195