Page 218 - Parker - Hydraulic and Lube Filtration Products
P. 218
Stationary Offl ine System
Performance Data
Efficiency
Beta Rating e i c i f f E n c y %
10000
Parker’s new
patented 2Q 5Q
Modufl ow™ Plus 10Q 99.9
1000
element was
designed with
99.5
200
built-in diverter
100 99.0
cone and bypass
valve, to meet
your application 20 95.0
needs.
2 5 0 . 0
0 4 8 12 16 20
Micron Size (c)
Applications Capacity
PSID B A R
• Oil & Gas 50
2Q
• Plastic Injection Molding 5Q
3.0
10Q
• Die Casting
40
• Steel 2.5
• General Industrial
• Power Generation 30 2.0
• Load Tap Changer
• Wind Turbines 1.5
20
• Transformer
• Mining 1.0
• Off-highway Equipment 10
0.5
• Food Processing
• Refi ning 0 0.0
• Paper Mills 0 20 40 60 80 100
• Aircraft Ground Support Capacity grams
Flow vs Pressure Loss
LPM LPM
0.0 5.0 10.0 15.0 0.0 5.0 10.0 15.0
1.0
5
150SUS
150SUS
0.06
Empty Housing
0.30
0.8
4
0.05
0.25
3 0.20 0.6 0.04
PSID BAR PSID BAR
0.03
0.15 0.4
2
2Q 0.02
0.10
1 0.2
5Q 0.01
0.05
10Q
0 0.00 0.0 0.00
0 1 2 3 4 5 0 1 2 3 4 5
GPM GPM
213