Page 241 - Parker - Hydraulic and Lube Filtration Products
P. 241
Reservoir Accessories
Breathers
Installation Air Flow Performance
TriCeptor breathers are designed for simple installation The curves below show the air fl ow performance of the
on most equipment, regardless of mounting connection. three TriCeptor breathers. To insure the longest life
Since TriCeptor breathers are disposable, the threaded possible, the initial clean pressure drop should not
connection allows for quick and easy maintenance. Several exceed 1.5 psid (.103 bar).
mounting adapters (shown below) are available to provide
the desired mounting. The installation/replacement pro- 3.5 .241
cess consists of four easy steps:
3.0 .207
1. Remove from protective plastic wrap. 2.5 .172
2. Remove 1" blue cap from standpipe.
2.0 .138
3. Remove foil label to expose the necessary PSID BAR
amount of air intake holes. 1.5 .103
4. Twist TriCeptor into mounting adapter. 1.0 .068
.5 .034
Servicing the TriCeptor breather is also very easy. When
the silica gel changes color from blue to a pink, the 0 0 30 60 90 120 150
breather is no longer active and needs to be replaced. GPM (fluid exchange rate)
Simply remove the unit and discard properly.
3.5 .241
3.0 .207
101.60
4.00
2.5 .172
2.0 .138
PSID BAR
1.5 .103
1.0 .068
.5 .034
0
0 4 8 12 16 20
SCFM
'B'
0 1.88 3.78 5.66 7.55 9.44
'A' Liters/Second
O-RING
Field Adapter Flange Adapter
1" THREADED CONNECTION
Part Number ‘A’ (mm/in) ‘B’ (mm/in) Quantity
mm
Linear Measurement= 934330T 155.58/6.125 135.256/5.325 6 pcs.
in
934331T 206.38/8.125 186.06/7.325 6 pcs.
934332T 257.18/10.125 236.86/9.325 6 pcs.
937546 Field Adapter 937546 1 pc.
Drawings are for reference only.
Contact factory for current version. 937463 Flange Adapter 937463 1 pc.