Page 55 - Parker Parflex Thermoplastic & Fluoropolymer Products Hose, Tubing, & Fittings 2017 - Cat 4460
P. 55
HJK – Highjack Jackline Hybrid Hose A Hose
®
®
Features
10,000 psi Jack Hose
Certifications
MSHA Accepted
Meets I J-100 Requirements Tubing
B
Coiled Air Hose & Fittings
Applications/Markets
Used for high pressure jack line applications C
Not for high impulse applications
Part Nominal Maximum Maximum Minimum
Bend
Number I.D. O.D. Working Radius Weight
Pressure
Transportation
lbs
inch mm inch mm psi MPa inch mm lbs./ft. kg./mtr.
D
HJK04 1/4 6 .62 16 10,000 69 4.0 102 .27 .40
Construction Fittings
Tube: Copolyester HY Series - Available from Parker Hose Products Division
Reinforcement: Two braids of High Tensile Wire Connection configurations limited to: Male Pipe (01)
Cover: Smooth synthetic rubber For most Parker products, Crimp Die Selection charts can
be found online at www.parker.com/crimpsource Fittings
Operating Parameters
Temperature Range: Access instructions are on pg. G-14 E
• -40°F (-40°C) to +150°F (65°C) Colors
• Synthetic, synthetic blend, water, and water/oil emulsion Black
hydraulic fluids limited to +135°F (+57°C)
Vacuum Rating: 28 inch Hg Notes
Change in length at Max. Working Pressure: +/-2% Factory-made assemblies only
Min. Burst Pressure is 4x Max. Working Pressure at 73°F (23°C)
Tooling, Equipment
& Accessories
F
General Technical
For detailed ordering information, please consult price list or contact Parflex Division. G
Parker Hannifin Corporation | Parflex Division | Ravenna, Ohio | parker.com/pfd A-29