Page 16 - Parker - Series D1VW, B style 91 Design
P. 16
Bulletin HY14-2536-M1/US Directional Control Valves
Wiring Instructions Series D1VW, B Style
Plug-in Conduit Variation
Note: H, K and M styles shown
Wiring Instructions
(Dashed lines indicate wiring thru terminal strip – no assembly required here)
1. Install manaplug (Item 1) over solenoid "A" on double solenoid models (opposite solenoid on single solenoid
models).
2. Slip ground screw (1301070) through ring terminal on green ground wire (from manaplug) and secure to valve
body.
3. Insert manapug wires into terminal strip (Item 3) in box as shown in wiring diagram. Ensure all wire strands are
contained by the connector and tighten clamping screws to 0.5 Nm (5 in. lbs.).
4. Install cover on the conduit box.
5. Place warning label (Item 2) on conduit box side, as shown.
Bul HY14-2536-M1.indd, dd
13 Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA