Page 2 - Parker - Fulflo ProBond Filter Cartridges (2008)
P. 2

®
     Fulflo  ProBond Filter Cartridges

     Specifications                       Particle Removal Ratings:               ProBond Flow      ProBond Length
                                             2µm, 5µm, 10µm, 25µm, 50µm, 75µm,        Factors           Factors

     Materials of Construction:               125µm and 150µm                     Rating   Flow      Length  Length
       1st stage Pre-filter wrap: Polyester/Acryl-                                (µm)   Factors       (in)    Factor
                                          Dimensions, in (mm):
        ic long staple fiber blend
       2nd stage Final Filter wrap: Acrylic long   Outside Diameter: 2-9/16 in (65)   2  0.08         9      1.0
        staple fiber                         Inside Diameter: 1-1/8 in (28.6)     5      0.04         10     1.0
       Fibers impregnated with Phenolic Resin  Lengths: Nominal, 10, 20, 30 and 40 in   10  0.02      19     2.0
                                              lengths
                                                                                  25     0.012        20     2.0
       Type of Construction:              Environmental/Chemical Compatibility:   50     0.01         29     3.0
       Coreless, one-piece, rigid resin bonded   Classified as a nonhazardous material   75  0.006    30     3.0
        fibrous matrix                        Incinerable (8000 BTU/lb)           125    0.0013       39     4.0
                                              Crushable and shredable
     Maximum Recommended Operating            Certified silicone-free             150    0.0010       40     4.0
     Conditions:
                                              Suitable for weak acids and bases
       Flow Rate: 5 gpm per 10 in length                                         Flow Rate and Pressure Drop Formulas
        (18.9 lpm per 254 mm length)          (pH 5-9)                          Flow Rate (gpm)  =  Clean  P x Length Factor
       Temperature: 250°F (121°C)             Unsuitable for oxidizing agents                  Viscosity x Flow Factor
                                              Not recommended for FDA applications
       Maximum Recommended                                                      Clean DP  =  Flow Rate x Viscosity x Flow Factor
                                          End Adapters:                                          Length Factor
       Recommended Maximum Differential      None on double open end style
        Pressure:                            ABS (Acrylonitrile Butadiene Styrene) for   1. Clean  P is PSI differential at start.
                                                                                2. Viscosity is centistokes. Use Conversion
       Cartridge Pressure Resistance:         most applications                   Tables for other units.
        150 psid (10 bar) @ 70°F (21°C)      Nylon (NTC) for aromatic solvents  3. Flow Factor is  P/GPM at 1 cks for 10 in
        125 psid (8.6 bar) @ 100°F (38°C)                                         (or single).
        90 psid (6.2 bar) @ 150°F (65°C)                                        4. Length Factors convert flow or  P from 10 in
        65 psid (4.5 bar) @ 180°F (82°C)                                          (single length) to required cartridge length.
        25 psid (1.7 bar) @ 250°F (121°C)













     Ordering Information

                   PRO

                 Cartridge Code  Micron Rating (µm)  Length       End Cap Configurations   Seal Material
                 PRO = ProBond     2         (code)   (in)   (series)  Omit =  Standard DOE (coreless)  Omit = DOE and XA
                    Series         5          9    9-3/4   248  CXC =  ExtendedTinned Steel Core  E = EPR
                                   10         10   10      254  C =    Tinned Steel Core  N = Buna-N
                                   25         19   19-1/2   495  NTC =  Single Open End 222  S = Silicone (O-Ring only)
                                   50         20   20      508      O-ring/Flat Cap (Nylon)  T = PFA Encapsulated
                                   75         29   29-1/4   743  OB =  Std. Open End/Polypro  Viton* (222, 226
                                   125        30   30      762      Spring Closed End    O-Ring Only)
                                   150        39   39      961  TC =   Single Open End  V = Viton*
                                              39   39      991  XA =   222 O-Ring/Flat Cap  W = Poly Foam Gaskets
                                              40   40      1016     (ABS Plastic)
                                                                XB =  Poly Extender
                                                                    Ext. Core Open End/
                                                                    Polypro Spring Closed End


     Specifications are subject to change without notification.                             © 2008 Parker Hannafin
     *Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.                 Process Advanced Filtration Inc.
                                                                                            All Rights Reserved
                                                                                            SPEC-C1620-Rev. A 01/08


                                                                    ENGINEERING YOUR SUCCESS.

                                                             66
   1   2