Page 2 - Parker - Fulflo ProBond Filter Cartridges (2008)
P. 2
®
Fulflo ProBond Filter Cartridges
Specifications Particle Removal Ratings: ProBond Flow ProBond Length
2µm, 5µm, 10µm, 25µm, 50µm, 75µm, Factors Factors
Materials of Construction: 125µm and 150µm Rating Flow Length Length
1st stage Pre-filter wrap: Polyester/Acryl- (µm) Factors (in) Factor
Dimensions, in (mm):
ic long staple fiber blend
2nd stage Final Filter wrap: Acrylic long Outside Diameter: 2-9/16 in (65) 2 0.08 9 1.0
staple fiber Inside Diameter: 1-1/8 in (28.6) 5 0.04 10 1.0
Fibers impregnated with Phenolic Resin Lengths: Nominal, 10, 20, 30 and 40 in 10 0.02 19 2.0
lengths
25 0.012 20 2.0
Type of Construction: Environmental/Chemical Compatibility: 50 0.01 29 3.0
Coreless, one-piece, rigid resin bonded Classified as a nonhazardous material 75 0.006 30 3.0
fibrous matrix Incinerable (8000 BTU/lb) 125 0.0013 39 4.0
Crushable and shredable
Maximum Recommended Operating Certified silicone-free 150 0.0010 40 4.0
Conditions:
Suitable for weak acids and bases
Flow Rate: 5 gpm per 10 in length Flow Rate and Pressure Drop Formulas
(18.9 lpm per 254 mm length) (pH 5-9) Flow Rate (gpm) = Clean P x Length Factor
Temperature: 250°F (121°C) Unsuitable for oxidizing agents Viscosity x Flow Factor
Not recommended for FDA applications
Maximum Recommended Clean DP = Flow Rate x Viscosity x Flow Factor
End Adapters: Length Factor
Recommended Maximum Differential None on double open end style
Pressure: ABS (Acrylonitrile Butadiene Styrene) for 1. Clean P is PSI differential at start.
2. Viscosity is centistokes. Use Conversion
Cartridge Pressure Resistance: most applications Tables for other units.
150 psid (10 bar) @ 70°F (21°C) Nylon (NTC) for aromatic solvents 3. Flow Factor is P/GPM at 1 cks for 10 in
125 psid (8.6 bar) @ 100°F (38°C) (or single).
90 psid (6.2 bar) @ 150°F (65°C) 4. Length Factors convert flow or P from 10 in
65 psid (4.5 bar) @ 180°F (82°C) (single length) to required cartridge length.
25 psid (1.7 bar) @ 250°F (121°C)
Ordering Information
PRO
Cartridge Code Micron Rating (µm) Length End Cap Configurations Seal Material
PRO = ProBond 2 (code) (in) (series) Omit = Standard DOE (coreless) Omit = DOE and XA
Series 5 9 9-3/4 248 CXC = ExtendedTinned Steel Core E = EPR
10 10 10 254 C = Tinned Steel Core N = Buna-N
25 19 19-1/2 495 NTC = Single Open End 222 S = Silicone (O-Ring only)
50 20 20 508 O-ring/Flat Cap (Nylon) T = PFA Encapsulated
75 29 29-1/4 743 OB = Std. Open End/Polypro Viton* (222, 226
125 30 30 762 Spring Closed End O-Ring Only)
150 39 39 961 TC = Single Open End V = Viton*
39 39 991 XA = 222 O-Ring/Flat Cap W = Poly Foam Gaskets
40 40 1016 (ABS Plastic)
XB = Poly Extender
Ext. Core Open End/
Polypro Spring Closed End
Specifications are subject to change without notification. © 2008 Parker Hannafin
*Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc. Process Advanced Filtration Inc.
All Rights Reserved
SPEC-C1620-Rev. A 01/08
ENGINEERING YOUR SUCCESS.
66