Page 45 - Parker - Compact Hydraulic Cylinders
P. 45
Catalog HY08-1137-7/NA Compact Hydraulic Cylinders
End-Of-Stroke Switch Series CHD
EPS-C Threaded Style End-of-Stroke Switch
Optional high pressure inductive switches provide an end-
View
Table of of stroke signal in Series CHD cylinders. Available on both
Contents ends or one end only, EPS-C switches are low profile and
can be specified on any of the four sides of the cylinder,
except Styles C and CN where they are only available at port
position #1.
EPS-C Switch Specifications
Switch Type: Inductive Proximity EPS-C Switch Dimensions
Style: EPS-C Bore EN HS
Ø
Code Designator: J
25 17 50.5
Description: General Purpose, 3 wire, DC Sensor
32 20 54
Supply Voltage: 10 to 30 VDC
40 21 58
Load Current, max.: 100 mA
50 23.5 63
Leak Current: 100 µA 63 26.5 69.5
Voltage Drop: ≤ 2.5 V 80 30 78
Operating Temperature: -13° F to +176°F 1
Part Number: 0961930000 15°
15°
Connection: .3m Lead with 8mm Connector
Enclosure Rating: Enclosure - IP68 EN EN
Led Indication: No HS
Short Circuit Protection: Yes 4 2
Weld Field Immunity: Yes
Output: PNP 3
Approvals/Marks: CE Bores 25 – 80
Position 1 only
Make/Break Location: 0.25" from end of stroke typical. (Styles C & CN position 1 only)
Tolerance is +0 / -0.13"
4 Note: Switch installation at 15° angle is only required when
bn 1 + specified at position 1 (same position as ports).
Wiring Instructions: bk 4 DC 1 3 1
bu 3 –
EPS-C limit switches may be ordered as follows: 4 2
1) Complete the basic cylinder model number. EN EN
2) Place an “S” in the model number for Special Modification.
3) Special modifications to cylinders other than switches HS
must be described in the item notes. Bores 25 – 80 3
4) Limit Switch Code – Specify letter prefix “J” for EPS-C Positions 2 – 4
then fill in the four blanks specifying port location, switch (Styles C & CN position 1 only)
location and actuation point for both head and cap. If only
one switch is used, place “XXXX” in the unused blanks. 8mm Cordset
Example = J13GG-XXXX denotes a switch on the Gland
Snap On
Threaded
end only. Cable Length Connector Connector
Example = XXXX-J42GG denotes a switch on the cap 5 meters 086620T005 086620S005
end only. 2 meters 086620T002 086620S002
Limit Switch Code
Head End Cap End
J 1 1 2 GG 1 1 2 GG
Actuation Point Actuation Point
Specify: J=EPS-C Port Location Switch Location GG= End Port Location Switch Location GG= End
of Stroke of Stroke
1 Ports must always be specified in position 1.
42 Parker Hannifin Corporation
Industrial Cylinder Division
www.parker.com/cylinder Des Plaines, Illinois USA