Page 5 - Haskel - High-pressure customized solutions for the oil and gas industry's liquid and gas transfer, storage and controlling applications
P. 5
Fire Protection/Detection Dry Gas Seal Safety Systems AIR PRESSURE AMPLIFIER
& APPLICATIONS
actuators within remotely piloted valves along Haskel pumps are used for rapid and precise Centrifugal compressors equipped with dry Fire Fighting: The SafetyAmp breathing-air
Operating in the complex world of oil and gas, Haskel is a pipeline system. This pressure compresses filling of Halon 1211 (BCF), Halon 1301 (BTM) gas seals use the process gas as a seal gas. booster compresses breathing-air up to 345 Air Amplifiers
bar (5,000 psi) for use in rescue work.
During normal operation, the compression
the actuator springs, keeping the valves in an
and liquid carbon dioxide extinguishers.
committed to maintaining a simple approach to business, open condition. While in this condition, there is The pump, which transfers and pressurizes of the gas generates heat, pressure and flow Life Support: Our specialty boosters fill • Haskel air amplifiers are compact,
focusing on three key factors: understanding our customers no heat generated or energy consumed, and no the Halon, is designed to automatically to the seal, preventing contamination and resuscitation cylinders with oxygen for use in require no electrical or mechanical drive
halt operation when the required weight
condensation. During start up or shut down,
wear to seals is incurred.
connections, and are powered by the
and their needs; delivering the highest quality products; and If a pressure abnormality occurs, the hydraulic (pressure) is achieved. Where nitrogen is however, these conditions are not met and the life-support applications. same air that they amplify. Available with
dedication to innovation. pressure is dumped and the valve closes in a used as a propellant, Halon is pumped into seal is at risk of contamination specifically from Survival Craft: Haskel air boosters inflate and pressure outputs to 5,000 psi (344 bar).
pressurize totally enclosed survival craft that
heavy condensate.
the extinguisher against the pressure of the
fail-safe condition. Diesel Engine Starter Air Amplifier
nitrogen, instantly mixing the two. Haskel pumps submerge and resurface.
This methodology has led us to become performance and extended product life. can also extract high-cost Halon vapor from the Haskel dry seal gas boosters are used to ensure Haskel air amplifiers can be used to charge an
the global leader in providing customized As operating environments become more supplier’s container and convert the vapor pack seals are pressurized with dry gas during start Helicopter Bootstrap: Nitrogen or helium-fed air cylinder from a standard air-line to 35 bar HIGH-PRESSURE VALVES &
solutions for high-pressure liquid and gas extreme, pressures increase and field to liquid by passing through a condenser. up and shut down preventing damage to the boosters automatically inflate floats, in the event (500 psi) for air-starting oilfield and marine SYSTEM COMPONENTS
transfer, storage and controlling applications. life expectancy grows, we continue to seal from contaminants. that the helicopter needs to land on water. diesel engines.
Designed to enable the controlled use of deliver products that empower oil and gas Boosters detect hot-spots using pressurized Nitrogen Gas Pressure Testing Diving Haskel gas boosters and amplifiers are used in A complete family of high-pressure controls
argon supply cylinders attached to infrared
pressure and flow-generating equipment, Haskel companies to operate effectively, while viewers. Haskel air-driven gas boosters are used to Haskel air-driven gas boosters pressurize gas helium recovery, deep-sea diving operations, and system components to complement
air or gas driven liquid pumps, gas boosters, air simultaneously allowing them to meet the pressurize a wide range of gas pressure- for offshore deep-sea diving operations. Gas leak detection, well emergency shut down Haskel’s extensive line of pumps, gas
amplifiers, and high-pressure accessories are stringent safety regulations that protect maintaining devices both on and offshore. boosters can be arranged in series or in parallel systems, topping of accumulators with boosters, and air pressure amplifiers.
the most comprehensive range of high-pressure their personnel and the environment. GAS BOOSTERS & APPLICATIONS Anything from relief valves, pipe spools, and to achieve the required flow combinations of nitrogen, operating oxygen concentrators,
liquid or gas handling components available An international network of highly trained small pressure vessels are tested with nitrogen pressurized gases including oxygen, nitrox electrical circuit breaker installations, starting Panel fabricators, control panel shops and
to facilitate the construction of test systems distributors, with application engineering Liquid Pump Gas Boosters gas to prove they are leak tight before being put and helium. Haskel gas boosters are noted for diesel engines, and fire protection. OEMs use Haskel accessories to control or
store pressure and flow.
and custom built rigs that meet the exacting expertise, stand behind our products.
standards of the oil and gas industry. • Haskel air-driven and hydraulic-driven into service on gas production facilities. their cleanliness and can handle pure gases, • Check valves to control direction and flow
These professionals ensure that our Well Emergency Shut Down Systems gas boosters provide high-pressure such as oxygen, without risk of contamination.
Operators and service companies worldwide customers’ expectations are met with gas transfer, charging and storage of Nitrogen Gas Accumulator Charging • Relief valves to protect against over-
Wall-mounted pressure test rig rely on our products to deliver optimum a solution specific for their needs. Haskel pumps deliver foolproof, fail-safe pressures up to 2,700 bar (39,000 Nitrogen gas boosters are used for charging Gas boosters for breathing air applications pressurization of systems
protection against the serious health and safety psi). These boosters offer a flexible and are oxygen cleaned per Mil Spec 1330, for • High Pressures 10,000 psi (690 bar)
problems presented by working with high efficient source for delivering high- nitrogen filled accumulators and pulsation oxygen use.
pressures in conjunction with explosive and pressure gases such as argon, nitrogen, dampeners. As pressures increase within the accumulators to store hydraulics fluid
toxic products. oxygen, hydrogen, helium, carbon industry, the need for higher pre-charge on gas Chemical Injection as energy source
dioxide, liquefied gas and many other accumulators becomes more commonplace. Different types of chemical injection equipment
LIQUID PUMPS & APPLICATIONS During exploration drilling, Haskel pumps specialty gases. Often, the gas pressure supply from commercially
can provide hydraulic power to actuate a kill filled gas cylinders is in excess of 500 bar are required for different applications, and we
feature low, medium and high flow systems.
Liquid Pumps or choke system. Pumps generate hydraulic • Our boosters are ideal for gas (7,200 psi), lower than the pre-charge required.
pressure to actuate a downhole ball valve pressure increases, high-pressure gas The unique Haskel injection rate control device
• Haskel pneumatic pumps stall when they or flapper valve that automatically closes if a transference, cylinder charging and Haskel gas boosters have the capability to (IRCD) has been designed for single and multi-
charge to pressures in the region of 1,000 bar
reach a pre- determined pressure and pressure surge or abnormally high pressure scavenging. (14,500 psi) advantageously using most of the point chemical regulation.
maintain that pressure for the duration is experienced.
of operation without consuming power, In the event of a well blowout, Haskel pumps gas in the supply cylinder. IRCD Capacity
unlike electric motor pumps that dump Barrier Gas Seal Low flow specifications:
fluid across a relief valve, wasting energy are used to pressurize banks of nitrogen-filled • 15,000 psig (1034 bar)
and creating heat. Because of this safe accumulators with hydraulic oil to activate the Nitrogen gas is typically used as a gaseous
air operation, no heat, flame, or spark risk blowout preventer. buffer on some gas-lubricated mechanical maximum operating pressure
arises. seals. The buffer gas prevents process leakage • 0.5 to 320 LPH flow range (0.13 - 84 GPH)
to the atmosphere, can prevent ice in low Medium flow specifications:
• Haskel pneumatic pumps have a smaller temperatures and helps avoid reaction of • 15,000 psig (1034 bar)
footprint, weigh less, and are easier to product leakage with the air. In high-pressure maximum operating pressure
maintain than typical electrically driven pumping applications, the buffer media needs to
pumps. be at a higher pressure than the process fluid. • 320 to 2000 LPH flow range (0.84 - 528 GPH)
Hydraulic Pressure Testing Helium Booster Haskel gas boosters are widely used to boost High flow specifications:
• 10,000 psig (690 bar)
Haskel pumps ensure the integrity of large Leak Detection the low-pressure nitrogen gas, automatically maximum operating pressure
valves and wellheads over the lifetime of a well. Gas Booster adjusting to the demand and providing a buffer • 2000 to 5000 LPH (528 - 1320 GPH)
Haskel gas boosters are used for high-pressure gas to the seal.
Hydraulic power units and other purpose-built Well Equalization System leak testing of underwater Christmas trees Haskel pumps are used for methanol injection
systems reliably test valves, components, pipe, and other subsea installations to ensure Multi-Booster Nitrogen Gas Systems where flows and pressure are higher.
downhole tools, and oilfield pressure vessels to During startup of both new and out of service hydrocarbons do not leak from the structure Gas boosters are ideal for nitrogen gas
stringent specifications, ensuring safe operation. wells, the pipe from the platform and/or FPSO and risk contaminating the sea or creating a fire generators and enabling storage within high-
Applications include proof, leak, burst, pulse, deck wellhead to the subsea wellhead located explosion. Helium gas is used at pressures up pressure gas cylinders. In periods of low
fatigue and calibration testing in a wide range of at the ocean floor must be pressurized to well to 2,000 bar (30,000 psi) because of its leak- demand, surplus gas can be transferred and
“As operating environments oilfield equipment and pipelines, including, but pressure before the wellhead valves are opened. searching capabilities, particularly in detecting boosted into high-pressure storage vessels
become more extreme, Haskel not limited to, tanks, receivers, accumulators, In this application our 8 and 10 hp pumps inject porous castings. Sulphur hexafluoride (SF6) can where it can be kept and ready should gas be
continues to deliver products valves, piping, fittings, hoses and gauges. either diesel fuel or methanol line in order to also be used in leak detection gas. required to shut down the facility safely. The Air pilot switch
“equalize” the pressure both sides of the wellhead
that meet customer Valve Actuation Christmas tree valves. It is necessary to equalize high-pressure storage can also be used to
maintain production during routine maintenance
performance needs.” During normal running, hydraulic pressure from in order to prevent the sudden rush of pressurized of the nitrogen supply plant.
a Haskel pump can be used to pressurize valve hydrocarbon to the deck with is a safety issue.
“Because of our safe pneumatic operation, no heat, flame or spark risk arises.”