Page 13 - Linde - HPV-02 Variable pumps for closed loop operation
P. 13
Gear pumps.
The IGP charge pumps include a cold start relief valve and a through drive for attaching additional pumps. The suction can be
internal, external or combined. IGP types are available in rated sizes of 16 cc/rev and 22.5 cc/rev.
Internal gear pump IGP with internal suction
Internal suction External suction Combined suction
A A A
HPV-02 HPV-02 HPV-02
B B
>> Internal suction
The charge pump supplies the main circuit with oil from the pump housing.
External connection B is closed.
>> External suction
The charge pump supplies the main circuit with oil from the oil tank.
Ther internal connection is closed.
>> Combined suction
The charge pump supplies the main circuit with oil from the pump housing and oil tank.
This type of suction is a combination of internal and external suction.
13