Page 20 - Linde - HPV-02 Variable pumps for closed loop operation
P. 20

Controls. Hydraulic H


            Pilot pressure range                standard: 4-16 bar, option: 4-10 bar differential pressure |Y-Z|
            Maximum permissible pressure at Y or Z   30 bar
            Minimum response time with standard orifices
            for one-way swashing between 0 and max   0.5 s
            Displacement relative to pilot pressure



                  100




                   80





                Displacement [%]  60                                             Standard: 4 - 16 bar




                   40
                                                                                 Option: 4 - 10 bar




                   20





                   0
                              2        4        6        8        10       12       14       16       18
                                                    Pilot pressure ∆p = IY-ZI [bar]




            H1P-control with PCO




































      20
   15   16   17   18   19   20   21   22   23   24   25