Page 26 - Linde - HMF/A/V/R-02 Hydraulic motors for closed and open loop operation
P. 26
Motor types. HMV-02 H2 and E2 two position
Two position motors are suitable for open and closed loop operation. Without control signal they are set to maximum displacement
V max. Adjustment between V min and V max is smooth and with short response time. The required switching signal can optionally be
hydraulic or electric, the servo pressure supply internal or external, see section Functions. Servo pressure supply. The following
data are independent of the rated motor size.
Two position control features
Minimum tripping bar 20
External servo
pressure supply
Maximum permissible tripping bar 40
Shifting pressure
Hydraulic Minimum tripping bar 20
control Shifting pressure bar 40
Maximum permissible tripping
DIN EN 175301-803, Deutsch,
Connector type
AMP Junior Timer, (2-pin, Cod.2)
Rated voltage = max. continuous voltage V 12 24
Voltage type DC voltage
Electric Control
Power input (cold) W ≤ 26
Relative duty cycle % 100
Protection class IP54 (DIN), IP67 (Deutsch), IP 6K6K (AMP)
Minimum response time with standard orifice s 0.5 - 1
with 20 bar servo pressure
Two position motor with hydraulic control pressure
and external servo supply pressure
A,B Work port connections
max L,U Case drain/vent
connections
Displacement E Servo supply pressure
connection
min
X Control connection
0 max
Control signal
26