Page 2 - Parker - ProFlow II ABR
P. 2
PrOflOW II ABr
™
Pleated PTFe membrane cartridge for sterile venting and gas delivery
PERFoRMancE attRiBUtEs
Air in flow rates, Typical * Air Flow (Nm /h)
3
10 inch (250 mm) cartridges 0 20 40 60 80
0.1 µm 40 scfm/psid (98.5 Nm /h/100 mbar) 2.5
3
0.2 µm 55 scfm/psid (135.4 Nm /h/100 mbar)
3
0.45 µm 90 scfm/psid (221.6 Nm /h/100 mbar) 150
3
1.0 µm 90 scfm/psid (221.6 Nm /h/100 mbar) 2
3
Differential Pressure (psid) 1 10", 0.1 m 100 Differential Pressure (mbar)
*At 75ºF (24ºC) and an inlet pressure of 15 psia (1 bar) 1.5 5", 0.2 m
0.5 10", 0.2 m 50
10", 0.45 & 1.0 m
0 0
0 10 20 30 40 50
Air Flow (scfm)
oRDERinG inFoRMation
Each cartridge is identified with a product number, pore size and lot number for traceability.
34 0 A
Insert Style End Fitting Nominal Length Filter Rating O-ring Material
CODE DESCRIPTION CODE DESCRIPTION CODE Length (mm) CODE (µm) CODE DESCRIPTION
5 Encapsulated 2 226/Flat 05* 5” (130) 002 0.2 0 Buna N
Stainless Steel 3 222/Flat 10 10” (250) 004 0.45 1 EPR
6 Encapsulated 7 226/Fin 20 20” (500) 010 1.0 2 Silicone
Polysulfone (std) 8 222/Fin 30 30” (750) 4 Viton ®
40 40” (1000) 5 FEP Encapsulated Viton ®
* 5 inch (130 mm) cartridge available 6 FEP Encapsulated Silicone
only in the 0.2 μm rating. All cartridges N None
are 2.75 inches (70 mm) O.D.
tEcHnical sUPPoRt anD PRoDUct inFoRMation
Parker provides our customers with unsurpassed product consistency and cost efficiency. Our experienced professionals can help you select the right
solution for your application. Orders can be emailed directly to PAFsales@parker.com. For additional information contact your local distributor. Information
on product specifications, applications and chemical compatibility can be found on our web site at www.parker.com or through the Oxnard office.
Parker designs and manufactures an extensive line of innovative solutions for specific applications in the Microelectronics, Biopharmaceutical, Food and
Beverage, Coatings and Inks, Process and Chemical industries.
DISTRIBUTED BY:
Process Advanced Filtration Division
2340 Eastman Avenue
Oxnard, California, USA 93030
Toll Free: +1 877 784 2234
Specifications are subject to change without notification. Phone: +1 805 604 3400
© 2007 Parker Hannifin Corporation. Fax: +1 805 604 3401
Proflow TM is a trademark of Parker Hannifin Corporation.
Viton ® is a registered trademark of E.I. DuPont de Nemours and Co., Inc. PAFsales@parker.com
www.parker.com