Page 89 - Shroeder - Filter Systems
P. 89
Air-Operated Mobile Filtration Systems AMS
AMD TCM
U.S. Patents 6568919 7604738
TCM-FC
■ Supplementing continuous filtration by system filters Applications
■ Cleaning up a hydraulic system following component replacement HY-TRAX ®
■ Filtering new fluid before it is put into service
TWS
■ Transferring fluid from storage tanks and drums to system reservoirs
■ Field applications on service trucks TMS
Flow Rating: 7 gpm (26.5 L/min) max and 14 gpm (53.0 L/min) max Specifications SMU
Maximum Viscosity: 1,000 SUS (216 cSt)
Higher viscosity version available. Contact factory for details. TSU
1
Housing Pressure Rating: 250 psi (17.2 bar) max operating
1,000 psi (68.9 bar) min yield TMU
Fluid Temperature: 25°F to 150°F (-4°C to 65°C) 2
Bypass Valve Setting: Cracking: 30 psi (2 bar) TPM
Material: Manifold and cap: Cast aluminum
Element case: Steel TIM
Compatibility: All petroleum based hydraulic fluid. Contact factory
for use with other fluids. HMG 3010
Element Change Clearance: 8.50” (215 mm) 1K (9, 18 or 27” depending on model configuration)
1 For higher hose pressure applications contact factory. ET-100-6
2 For higher temperature applications contact factory.
AMS-1K AMS-2K AMS-3K AMD-1K AMD-2K AMD-3K Weights CTU
GPM lb (kg) lb (kg) lb (kg) lb (kg) lb (kg) lb (kg)
7 170 (77) 180 (82) 190 (86) 185 (84) 203 (92) 220 (100) EPK
14 177 (80) 187 (85) 197 (89) 192 (87) 210 (95) 227 (103) Trouble
Check Plus
How to Build a Valid Model Number for Schroeder AMS: Model
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 Number HTB
AMS – – – – – – Selection
Example: NOTE: One option per box HFS
BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7
AMS – 1 – 09 – Z10 – Z05 – B – 14 = AMS109Z10Z05B14 MFS, MFD
BOX 1 BOX 2 BOX 3 BOX 4 MFS-HV, MFD-HV
Model No. of Elements Element Length Element Media First Filter MFDBC
AMS 1 09 E03 = 3 μm E-Media (cellulose)
2 18 E10 = 10 μm E-Media (cellulose) AMS, AMD
AMD 3 27 E25 = 25 μm E-Media (cellulose) ®
®
Z01 = 1 μm Excellement Z-Media (synthetic) FS
®
Z03 = 3 μm Excellement Z-Media (synthetic)
®
®
®
Z05 = 5 μm Excellement Z-Media (synthetic) AMFS
®
®
Z10 = 10 μm Excellement Z-Media (synthetic)
®
®
Z25 = 25 μm Excellement Z-Media (synthetic) KLC
EWR = Water Removal
®
G03 = 3 μm Excellement Z-Media (synthetic) w/GeoSeal ® KLS, KLD
®
®
®
G05 = 5 μm Excellement Z-Media (synthetic) w/GeoSeal ® AKS, AKD
®
®
G10 = 10 μm Excellement Z-Media (synthetic) w/GeoSeal ® NOTES:
®
®
G25 = 25 μm Excellement Z-Media (synthetic) w/GeoSeal ® LSN, LSA, LSW
GWR = Water Removal w/GeoSeal ® Box 2 & 3. When Box
2 equals 2 or 3,
BOX 5 BOX 6 BOX 7 Box 3 must be X Series
09.
Element Media Second Filter (AMD Only) Seal Material Pump Size(gpm)
E03 = 3 μm E-Media (cellulose) B = Buna 07 Box 5. When AMD is MTS
E10 = 10 μm E-Media (cellulose) 14 ordered, the Triton-A
E25 = 25 μm E-Media (cellulose) number of
elements,
®
Z01 = 1 μm Excellement Z-Media (synthetic) element Triton-E
®
®
Z03 = 3 μm Excellement Z-Media (synthetic) length, and seal
®
®
Z05 = 5 μm Excellement Z-Media (synthetic) will be identical SVD01
®
for both filter
®
Z10 = 10 μm Excellement Z-Media (synthetic) housings.
®
®
Z25 = 25 μm Excellement Z-Media (synthetic) SVD
®
EWR = Water Removal Box 7.
®
G03 = 3 μm Excellement Z-Media (synthetic) w/GeoSeal ® 07 GPM - 50 CFM at 70 psi IXU
®
®
®
G05 = 5 μm Excellement Z-Media (synthetic) w/GeoSeal ® 14 GPM - 70 CFM at 70 psi
®
®
G10 = 10 μm Excellement Z-Media (synthetic) w/GeoSeal ®
®
G25 = 25 μm Excellement Z-Media (synthetic) w/GeoSeal ® Appendix
®
GWR = Water Removal w/GeoSeal ®
SCHROEDER INDUSTRIES