Page 2 - Parker - Fluorocap-XF
P. 2

Fluorocap -XF
                          ®

     Specifications                       Performance	Attributes
     Materials	of	Construction            Water	Flow	rates,	Typical	*	          Cleanliness	(particle	shedding)
     Asymmetric.PTFE.membrane.            SELECT. 7.8gpm/psid.(52.2lpm/00mbar)..  Wet-packed:....<2.particles/ml.>0.2µm.after.
     00%.Fluoropolymer.construct.        Standard.. 4.7gpm/psid.(3.3lpm/00mbar).        5gal.at.gpm
     All.components.are.thermally.bonded.to.ensure.  *Flow.rates.are.for.in-line.Fluorocaps.with.  Dry-packed:....<2.particles/ml.>0.2µm.after.
     integrity.and.reduce.extractables.                                                    7gal.at.gpm
                                          3/4”.Parflare.fittings.               TOC/Resistivity	Rinse-up	(wet-packed)
     Effective	Filtration	Area                                                  TOC.recovery.within.3-5ppb.of.feed.after.
     .4ft².(.03m²).per.0".(250mm).                                          2gal.@.gpm..Resistivity.recovery.within.
                                                                                0.4megohm-cm.of.feed.after.22gal.@.gpm..
     Metals	Extractables*
     Standard:.<20ppb.(total).              Flow	Direction	Options
     Ultraclean:.<5ppb.(total)            	  T	       L	       R
     *in.a.0%.HNO3.extraction

     Maximum	Differential	Pressure/
     Temperature
     Forward:. .SELECT..80psi.(5.5bar).@.75°F.(24°C).
             Standard..60psi.(4.bar).@.75°F.(24°C)
     Forward.
     HT.Option:. .SELECT..2.5psi.(0.9bar).@.356°F.(80°C).
             Standard..20psi.(.3bar).@.356°F.(80°C)
     Reverse:. .SELECT..50psi.(3.4bar).@.75°F.(24°C).
             Standard..40psi.(2.8bar).@.75°F.(24°C)



     Ordering	Information
     Each.cartridge.is.identified.with.a.product.number,.pore.size.and.lot.number.for.traceability.

                  F

                                                                              *
            F   In-Line                   ˚                                           ˚
                                          ˚                              ˚
                                                                         ˚
                                                                         ˚









                                                                      *
                                         ˚
                                          ˚                  Y     SP300
                                                             F       3/4” Parflare
                                                             J       3/4” Flarelock®




           * Vent/Drain connections are  1 /4" versions of the inlet/outlet fittings,
              except for codes K and W which are  1 /2" Pillar vent/drain fittings.
     Specifications.are.subject.to.change.without.notification..                            ©.2008.Parker.Hannifin..
     FluoroCap.is.a.registered.trademark.of.Parker.Hannifin.Corporation..                   Process.Advanced.Filtration.Inc.
     Parflare.is.a.trademark.of.Parker.Hannifin.Corporation..                               All.Rights.Reserved
     FlareLock.is.a.trademark.of.Fluoroware,.Inc...                                         SPEC-FCAP-XF.Rev.B.04/08


                                                                    ENGINEERING.YOUR.SUCCESS.