P. 36
R7P Series
REGENAIR Regenerative Blowers
®
Model R7P3180M (parallel)
Max. pressure – 105 inH O (60 Hz), 90 inH O (50 Hz)
2 2
Max. vacuum – 95 inH O (60 Hz), 85 inH O (50 Hz)
2 2
Max. air flow – 795 CFM (60 Hz), 666 CFM (50 Hz)
PRODUCT FEATURES
• Rugged construction, low maintenance
• Oilless operation
• UL and CSA approved motor with permanently
sealed ball bearings
• Cast iron blower housing and cover. Cast aluminum impeller
• Smaller and less costly than two blowers
• Includes external mufflers for additional silencing AJ121M (2)
RECOMMENDED ACCESSORIES
• Pressure gauge AE133
• Two inlet filters AJ126G (pressure)
• Vacuum gauge AE134
• Vacuum gauge for monitoring inlet filter restriction AJ497
• Pressure/vacuum relief valve AG258F
• Silencer for vacuum relief valve AJ121G
• Inline filter AJ151M (vacuum)
• Liquid separator RMS400 (for vacuum line)
Product Dimensions (inches, mm)
Note: Unit must be mounted with shaft horizontal.
Note: Unit is stocked with plumbing arrangement of parallel compressor.
The end user may reverse intake and exhaust plumbing to make a vacuum unit.
28.47
723,14 31.87
14.23 809,50 18.00
361,44 4" NPT 457,20
2 x 10.00 7.25 Approx
254,0 Approx to 184,15
muffler
center line
2 1/2"
Pipe
20.12
511,05
16.62
422,15
4 x .56 Thru .18
9.23 10.00 14,22 10.00 4,57
234,44 254,00 254,00
11.24
285,50