Page 54 - Wieland - Safety: Safe system solutions for automation technology
P. 54
safe relay
SNZ 1022K
Two-hand relay type IIIA
Applications
• Protection of people and machinery
• Monitoring of two-hand applications
• Monitoring of safety gates
• According to EN 574 Type IIIA
• Up to PL c / Category 1 (EN ISO 13849-1)
• Up to SIL CL 1 (EN 62061)
Features
• Stop Category 0 according to EN 60204-1
• Two-channel actuation; 1 NO contact and
1 NC contact for each channel
• Cross monitoring
• Monitoring of synchronous activation
• 1 changeover contact
- ß Y t
Function
After the power supply is established at terminals A1/A2 the release current The device can only be restarted once the two actuators are returned to their
paths are closed when the actuators (S1+S2) are operated at the same time. initial positions (e.g. the two-hand buttons have been released). The current
The two actuators must be operated within 0.5 s to trigger a release. If just one status of the device is shown by 2 LEDs. The presence of the power supply is
of the two actuators is released, the device is immediately de-energized and indicated with the SUPPLY LED, the operation of the two actuators with the K1
the enabling current path is opening. LED, if there is synchronous operation.
Circuit diagram
SNZ 1022K
54