Page 54 - Wieland - Safety: Safe system solutions for automation technology
P. 54

safe relay




        SNZ 1022K
        Two-hand relay type IIIA



                                                              Applications
                                                              • Protection of people and machinery
                                                              • Monitoring of two-hand applications
                                                              • Monitoring of safety gates
                                                              • According to EN 574 Type IIIA
                                                              • Up to PL c / Category 1 (EN ISO 13849-1)
                                                              • Up to SIL CL 1 (EN 62061)


                                                              Features
                                                              • Stop Category 0 according to EN 60204-1
                                                              • Two-channel actuation; 1 NO contact and
                                                                1 NC contact for each channel
                                                              • Cross monitoring
                                                              • Monitoring of synchronous activation
                                                              • 1 changeover contact




                        - ß Y t





        Function
        After the power supply is established at terminals A1/A2 the release current   The device can only be restarted once the two actuators are returned to their
        paths are closed when the actuators (S1+S2) are operated at the same time.   initial positions (e.g. the two-hand buttons have been released). The current
        The two actuators must be operated within 0.5 s to trigger a release. If just one   status of the device is shown by 2 LEDs. The presence of the power supply is
        of the two actuators is released, the device is immediately de-energized and   indicated with the SUPPLY LED, the operation of the two actuators with the K1
        the enabling current path is opening.                 LED, if there is synchronous operation.













        Circuit diagram

           SNZ 1022K

























      54