Page 2 - Parker - MaxGuard select cartridges
P. 2

MaxGuard Select Cartridge



               MaxGuard Select Ultra-High Capacity Cartridge





               Specifications

               Liquid Particle Retention Ratings (µm) @ Removal Efficiency of:  MaxGuard Cartridge Flow
                                                                               Factors (psid/gpm @ 1 cks):
                     Cartridge    ß=5000    ß=1000   ß=100   ß=50   ß=20
                                  Absolute  99.90%   99%     98%    95%              Cartridge    Flow Factor
                     MGSP005        0.5      0.4      0.2    <0.2   <0.1             MGSP005        0.0900
                     MGSP020         2       1.4      0.4    0.2    <0.1             MGSP020        0.0300
                     MGSP050         5       3.8      1.2    0.3    <0.1             MGSP050        0.016
                     MGSP100        10        7       3      0.9    <0.2             MGSP100        0.011
                     MGSP200        20       18       5       2     <0.2             MGSP200        0.007
                     MGSP400        40       23       18      8     <0.7             MGSP400        0.003
                    MGSP1000        100      91       83      64     35             MGSP1000        0.001
                                                                               *Flow factors based on water at ambient
               Materials of Construction:      SELECT-Pleating                 temperature
               •  Media: MGSP (polypropylene),                                 SELECT pleating from Parker
               •  Support/Drainage:                                            Process Advanced Filtration
                 Polypropylene (MGSP), stainless                               provides an optimized
               •  Structural components:                                       effective filtration area,
                 Polypropylene (MGSP)                                          dramatically increasing flow
               •  Seal Material: Various                                       rates compared to products
                                                                               with standard pleat format.
               Dimensions:
               •  6.06 in (154 mm) OD
               •  1.92 in (49 mm) ID
               •  30 in (762 mm) long
               •  40 in (1016 mm) long

               Recommended Operating              MGSP
               Conditions:
               •  Maximum Temperature:          Cartridge Series  Micron Rating  Length  Seal Material  End Cap Configuration
                 MGSP - 176ºF (80ºC) @30 psid   MaxGuard Select  005 = 0.5  (code)  (in)  E = EPR  SM = 226/Flat
                 (2.1 bar)                                     020 = 2    30      30  N = Buna N  Cap w/Handle
               •  Maximum Differential Pressure:               050 = 5     40      40  V = Viton*
                 Forward:                                      100 = 10           S = Silicon
                                                                                  T = PFA/Viton
                 70 psid (4.8 bar) @ 77ºF (25ºC)               200 = 20
                                                               400 = 40
                 30 psid (2.1 bar) @ 176ºF (80ºC)              1000 = 100


               © 2008 Parker Hannifin Corporation                                                   XXXX         03/08