Page 2 - Parker - MaxGuard select cartridges
P. 2
MaxGuard Select Cartridge
MaxGuard Select Ultra-High Capacity Cartridge
Specifications
Liquid Particle Retention Ratings (µm) @ Removal Efficiency of: MaxGuard Cartridge Flow
Factors (psid/gpm @ 1 cks):
Cartridge ß=5000 ß=1000 ß=100 ß=50 ß=20
Absolute 99.90% 99% 98% 95% Cartridge Flow Factor
MGSP005 0.5 0.4 0.2 <0.2 <0.1 MGSP005 0.0900
MGSP020 2 1.4 0.4 0.2 <0.1 MGSP020 0.0300
MGSP050 5 3.8 1.2 0.3 <0.1 MGSP050 0.016
MGSP100 10 7 3 0.9 <0.2 MGSP100 0.011
MGSP200 20 18 5 2 <0.2 MGSP200 0.007
MGSP400 40 23 18 8 <0.7 MGSP400 0.003
MGSP1000 100 91 83 64 35 MGSP1000 0.001
*Flow factors based on water at ambient
Materials of Construction: SELECT-Pleating temperature
• Media: MGSP (polypropylene), SELECT pleating from Parker
• Support/Drainage: Process Advanced Filtration
Polypropylene (MGSP), stainless provides an optimized
• Structural components: effective filtration area,
Polypropylene (MGSP) dramatically increasing flow
• Seal Material: Various rates compared to products
with standard pleat format.
Dimensions:
• 6.06 in (154 mm) OD
• 1.92 in (49 mm) ID
• 30 in (762 mm) long
• 40 in (1016 mm) long
Recommended Operating MGSP
Conditions:
• Maximum Temperature: Cartridge Series Micron Rating Length Seal Material End Cap Configuration
MGSP - 176ºF (80ºC) @30 psid MaxGuard Select 005 = 0.5 (code) (in) E = EPR SM = 226/Flat
(2.1 bar) 020 = 2 30 30 N = Buna N Cap w/Handle
• Maximum Differential Pressure: 050 = 5 40 40 V = Viton*
Forward: 100 = 10 S = Silicon
T = PFA/Viton
70 psid (4.8 bar) @ 77ºF (25ºC) 200 = 20
400 = 40
30 psid (2.1 bar) @ 176ºF (80ºC) 1000 = 100
© 2008 Parker Hannifin Corporation XXXX 03/08