Page 10 - Gefran - Indicators, alarm units
P. 10
ALARM UNITS
40TB 40F 96 2400 2308
Temperature and pressure alarm unit Frequency Indicator Fast Indicator Multichannel Indicator
Front panel dimensions 96 x 96mm (1/4 DIN) 96 x 48mm (1/8 DIN) 96 x 48mm (1/8 DIN)
Inputs Number of analog inputs 2 1 mechanical contact, logic or alternating voltage drive 2 Main, 2 Auxiliaries 8
Sampling time 120 - 60 - 30 - 15msec Configurable frequency: 100KHz max. 2 msec (ch1, ch2) 10 msec (ch3, ch4) 900 msec
0,2% f.s. ±1digit for linear inputs;;
Precision 0,2% ±1 digit 0,1% in autorange mode ±1 digit with fixed f.s. 0,1% f.s. ±1digit (0,2% f.s. for TC)
0,5% f.s. ±1 digit for TC, RTD, mVac inputs
Maximum resolution 16000 pti - 100000 pti 4000 pti
0...20,0 sec + display hysteresis
Input filter Fixed 100Hz, may be cut out 0,0...20,00 sec input reading, 0,0...9,9 sec display Fisso 120 msec, may be cut out
0...9,9 scale points
Zero Offset Settable by user over entire scale range Settable by user over entire scale range -
Indicator of frequencies -1999...+9999 Indicator of frequencies 0...+9999 Indicator of pressure, forces, weight, shift, physical quantities Indicator of temperature and physical quantities -999...3000
Application
(settable decimal point) (automatic or settable decimal point) -19999...+99999 settable decimal point settable decimal point
J, K, T, E, N, S, R, B, LGost, U, G, D, C,Custom
Thermocouples Types - J, K, R,S, T with scale in °C or °F
with scale in °C or °F (IEC 584)
Cold junction compensation Internal, with automatic compensation - Internal / external Internal, with automatic compensation
Resistance thermometer Types Pt100 DIN43710 (3-wires), Pt100 Japan - Pt100 2/3-wires, scale in °C or °F
Thermistors Types PTC, NTC (1K/25°C) - -
0...20mA, 4...20mA, 0...60mV, 0...1V, 0...5V,
0...10V Ri > 500Ω for voltage signals ≤ 1V Ri > Strain-gauge: 5/10Vdc 200mA, 350Ω Potentiometer: ≥100Ω, Ri >10MΩ @ 2,5Vdc 0...20mV, 0...50mV, 0...100mV, 0...10V (Ri ±1MΩ);
0/4...20mA (Ri = 5Ω);
Linear Types 20KΩ for voltage signals - DcLinear: 0/4...20mA (Ri = 50Ω) ≤±100mV, Ri > 10MΩ; ±1V...±10V, Ri > 2MΩ); 100mVac, external dividers provided for signals up to 1500Vac
Auxiliary input: 0...10V (Ri ≥ 2MΩ); 0/4...20mA (Ri = 50Ω)
> 1V Ri = 50Ω for current signals Possible linearization on 64 segments and external shunt for 20Aac and 5Aac
Possible linearization on 32 segments
Input from potentiometer (min 100Ω)
Potentiometer - ≥100Ω, Ri > 10MΩ -
powered by instrument 1,2Vdc
Pressure probe Load cells Autorange sensitivity 1,5...3,3mV/V - Strain-gauge 350Ω; sensitivity 1,5...4mV/V -
Input from inductive or capacitive proximity encoder NAMUR 2
Frequency Type - -
or 3-wires limit switch. Input in alternating voltage 0,5...500V
Type - Input frequency ranges ≤ 20KHz -
Frequency meter with or whitout automatic scale and decimal
Display - point change, input frequency selectable in ranges: -
9.999; 99.99; 999.9; 9999
Revolution counter or frequency meter
Application - -
with programmable sampling time
Digital input Type 2 inputs from voltage-free contact Optoisolated passive PNP isolated 1500V 2, NPN, PNP,optoisolated, configurable function -
Application Tare zero, reset alarm latches, Hold, Flash Reset, Zero, Tare, Calibration, Loc/Rem, Hold, Flash -
max 2 relay or logic; can be expanded up to 10 relay or logic
Outputs max 3 max 4; can be expanded up to 10 relay or logic outputs with MD82
outputs with MD81
Relay NA max 5A, 250V resistive load cosφ = 1 5A/250V, contacts, resistive load cosφ= 1
Application Alarm units, alarms Alarm units, alarms
Logic Type - 11V Rout 220Ω(6V/20mA) 24Vdc (20mA, max.12V) 24Vdc Rout=47Ω (20mA, max.12V)
Application - Alarm units, alarms Alarm units, alarms
Triac Type - 24...240V ±10% 3A max. -
Application - Alarm units, alarms -
Isolated 1500V, 0/4...20mA, Rmax = 500Ω,±10V,
Analog Type 2 outputs: 0-10V, 0/4-20mA is.1500V,resolut.12 bit 4...20mA (R max 150Ω) resolution 12bit non isolated -
resolution 0,03%, configurable via software
Application Configurable Retransmission of variable PV, retransmission, auxiliary inputs, peak -
Isolated RS485 / RS232 (max 115200 baud), Isolated RS485 (1200-9600baud),current loop (1200baud),
Digital communication RS485, RS232 1200...19200 baud MODBUS RTU -
protocol MOD BUS RTU / PROFIBUS DP prot. MODBUS RTU
1,2Vdc for potentiometer > 100Ω ;5,10Vdc max.
Sensor or transmitter power supply 120A for strain gauge 15Vdc max/80mA; 24Vdc 24Vdc; ±10% not stabilized 50mA max Isolated 1500V, 5, 10Vdc/200mA o 24Vdc,±5% 100mA 10...15V, 100mA max.
max 50mA for transmitter 2-wires 5Vdc/120mA; 12Vdc/50mA max
100...240Vac/dc ± 10% 20...27Vac/dc ±10%
Power supply 11...27Vac/dc, 100...240Vac/dc; ±10% 50/60Hz 11...27Vac/dc ±10%; 100...240Vac/dc ±10% 50/60Hz, 10VA max., internal fuse
50/60Hz
Faceplate protection level IP65 IP65 IP54 (IP65 with protective cover)
Certifications UL UL -