Page 2 - Parker - Fulflo 2 Crypto Capsule
P. 2

fulflO  II CryPTO CAPsulE
                             ®

        Pleated PeS capsules for cryptosporidium removal from water

         PERFoRMancE attRiBUtEs
        Cartridges
                  temperature             Maximum Forward Δp
              °F
        ZCCS                °c     100  (bar)         (psi)
              68
                            20
                                         5.0
                                                      73
              104           40           4.0          58
                Nominal Length       End Caps
               CODE Length (mm)     CODE DESCRIPTION
                B   2.5” (65)        C   BF/ 226 Fin
                A   5” (125)         D   222/ Fin
                K   5” (125)         E   222/ Flat
                1   10” (250)        G   M-0 222/ recessed blind end cap
                2   20” (500)        R   S-28 222 (Tritab/ FIN)
                3   30” (750)        T   Trueseal126 (Tabbed/flat)
                4   40” (1000)       Y   Demi Stub 116 (Internal/flat)
                                     Z   Demi A & B Std.




        Capsules
         oRDERinG inFoRMation

         ZECS                 100                                    BN3


           Nominal Length                Inlet                 Outlet
         CODE  LENGTH (mm)       CODE  CONNECTION TYPE  CODE CONNECTION TYPE
          E   4.4” (113)          T    1” Tri-Clamp      T   1” Tri-Clamp
          B   5.5” (140)          N    1/2” NPT Male     N   1/2” NPT Male
          A   7.9” (200)          H    1/2” Hose barb    H   1/2” Hose barb
                                  G    Stepped Hose barb  G  Stepped Hose barb
                                  M    1/4” NPT Male     M   1/4” NPT Male


        Supplied in packs of 3




         tEcHnical sUPPoRt anD PRoDUct inFoRMation
        Parker provides our customers with unsurpassed product consistency and cost efficiency. Our experienced professionals can help you select the right
        solution for your application. Orders can be emailed directly to PAFsales@parker.com. For additional information contact your local distributor. Information
        on product specifications, applications and chemical compatibility can be found on our web site at www.parker.com or through the Oxnard office.
        Parker designs and manufactures an extensive line of innovative solutions for specific applications in the Microelectronics, Biopharmaceutical, Food and
        Beverage, Coatings and Inks, Process and Chemical industries.
         DISTRIBUTED BY:




                                                                                  Process Advanced Filtration Division
                                                                                  2340 Eastman Avenue
                                                                                  Oxnard, California, USA 93030
                                                                                   Toll Free: +1 877 784 2234
        Specifications are subject to change without notification.                 Phone: +1 805 604 3400
        Fulflo ®  is a registered trademark of Parker Hannifin Corporation.        Fax: +1 805 604 3401
        Viton ®  is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
        © 2007 Parker Hannifin Corporation.                                        PAFsales@parker.com
                                                                                   www.parker.com
        SPEC-FFll CCAP-FB Rev. A 9/07                        30