How to Specify EPS Proximity Switches
Parker EPS proximity switches may be ordered on 5) Specify letter prefix “H” for EPS-7, “D” for EPS-6,
Series 2H & 3H cylinders as follows: and “F” for CLS-1, or “B” for CLS-4, then fill in the
four blanks specifying port location, switch orientation
1) Complete the basic cylinder model number.
and actuation point for both head and cap. If only one
2) Place an “S” in the model number to denote switches switch is used, place “XXXX” in the unused blanks.
and/or special features. Example = H13CGG-XXXX denotes a switch on
3) Mounting styles D, DB, JJ, J, or H should be used the head end only, EPS-7
with caution because of possible mounting interferences. Example = XXXX-B42BGG denotes a switch on
Consult bulletin 0840-G-E1 for additional information.
the cap end only, CLS-4
4) Special modifications to cylinders other than switches
must have a written description.
Head End Cap End
H 1 3 A GG H 4 2 A GG
Specify: Port Switch Switch Actuation Specify: Port Switch Switch Actuation
“H” = EPS-7 Location Location Orientation Point “H” = EPS-7 Location Location Orientation Point
“D” = EPS-6 See See See GG = End “D” = EPS-6 See See See GG = End
“F” = CLS-1 1 Figure 1. Figure 1. Figure 2 of Stroke “F” = CLS-1 1 Figure 1. Figure 1. Figure 2 of Stroke
“B” = CLS-4 1 for EPS-7, FF = Stroke “B” = CLS-4 1 for EPS-7, FF = Stroke
EPS-6,
EPS-6,
“N” = Prep for CLS-1 and to Go; “N” = Prep for CLS-1 and to Go;
EPS-6 and EPS-7 CLS-4. See Bulletins EPS-6 and EPS-7 CLS-4. See Bulletins
switches 0840-G-E1, switches 0840-G-E1,
“P” = Prep for 2 or 3 for “P” = Prep for 2 or 3 for
CLS-1 and CLS-4 stroke CLS-1 and CLS-4 stroke
switches remaining. switches remaining.
“T” = Prep for “T” = Prep for
CLS-2 switch CLS-2 switch
Note: All specified switch and port locations are as seen from rod end of cylinder.