Page 38 - Alkon - Directional Control Air Valves & Accessories
P. 38

Keeping the world moving and working.



    O M N I  S E R I ES  V A L V ES


      OMNI 250 SERIES VALVES


      STACKING ARRANGEMENTS











































       NO. VALVES     A          B              VALVE STYLE             C           Example:
                                                                                    250 Stack Consisting of:
          2 or 3     5.00       3.38
                                         2 Pos. Single Solenoid Spring Return  5.86  (2)  250-02-003-03 air pilot
            4        5.00       4.25                                                (1)  250-02-003-68 DIN connector
            5         7.00       5.13                                               (1)  250-02-013-60Y grommet
                                           2 Pos. Single Solenoid Air Return  6.07
            6         7.00      6.00                                                (1)  250-02-003-03 air pilot
                                                                                    (1)  250-01-003-15 lever
            7        9.80       6.88
                                              2 Pos. Double Solenoid   7.70         (1)  250-02-013-37 conduit
            8        9.80        7.75                                               (1)  250-02-003-42 ex. proof
            9        9.80       8.63                                                (4)  250-1054 spacer plate
           10        9.80       9.50                                                (1)  250-1333 end plate assembly

      Note:  Horizontal end plates may be attached with either the mounting feet on the port side or the side opposite.
      Unless otherwise specified, all common wireway stacks have the mounting feet on the port side and all other
      stacks have the feet on the side opposite the ports. When ordering, if more than one model number valve is to
      be stacked, specify valve position by numbering valves from left to right while facing the “B end” operators. If a
      vertical mounting plate is used, number valves starting from vertical plate.







      38                                                                                          www.alkoncorp.com
   33   34   35   36   37   38   39   40   41   42   43