Page 152 - Parker - Vacuum products
P. 152
Catalog 0802-E Pressure Sensors
Caution, Accessories SCPSD High Pressure 316 Stainless Steel
Installation
Mechanical: Avoid static and dynamic over-pressures which exceed the
! CAUTION: Install and de-install the SCPSD only specified overload pressure. Even when the overload pressure
when there is no pressure present. is exceeded only for a short time the SCPSD may be damaged.
Attach the SCPSD to the appropriate process connection. Parker SensoControl diagnostic systems are recommended for
measuring pressure peaks exactly.
Installation should be undertaken only with a 22mm, across
flats spanner. Ensure that the digital display is placed in If there is a danger of excessively high pressure peaks, it is
the best viewing position by using the rotational housing recommended to:
adjustment. Turn the SCPSD manually to the required position. • use an SCPSD with a higher nominal instrument pressure
Maximum 290°. (analog output can then be correspondingly matched)
Excessive turning beyond the easily detectable end stop will • install a standard throttling device upstream from the SCPSD
lead to damage.
• The housing can be attached:
• with self-tapping screws into two blind holes at the back of
the housing
• with the mounting plate provided
C • with cable ties
Electrical:
! CAUTION: The SCPSD may be installed only by a
qualified electrician in accordance with the
respective national and international regulations. Error messages
Protect the SCPSD from electromagnetic influences and over- Display Description
voltages. The set value is lower than the other respective
Att parameters. When Enter is activated, the smaller value
Technical
Optional installation tips which are shown by experience to is matched up.
reduce the influence of interference:
Err1 System Error (Internal)
• Use shorter cables Nominal instrument pressure range was exceeded by
MPS-33
• Avoid short distances between connecting leads and power Err2 10%. Please check system pressure.
consuming devices and interference generating electrical Nominal instrument pressure range has been exceeded
and electronic equipment Err3 Error in analog electronics. Please check system
• Use free running diodes pressure.
MPS-34
Electrical test unit (M12, 5-Pin) SCPSD programming kit
SCP01
SCSN-450-PSD SCSD-PRG-KIT
SCPSD
Optical Interface Device that allows read / write and storing
of SCPSD configuration data. Kit includes optical interface
device, electrical test unit with PC cable (RS232 connector)
and software.
Glossary
Symbols,
Accessories,
Optical
Interface
Device
SCPSD
C22 Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics