Page 6 - Parker Hydraulic Filter - World Pressure Filters (WPF)
P. 6
WPF Series
WPF2 Element Performance
Capacity
100
150 SUS (32 cSt) 2Q
5Q 6.0
10Q
80
5.0
60 4.0
PSID BAR
40 3.0
2.0
20
1.0
0 0.0
0 5 10 15 20 25
Grams
Flow vs. Pressure Drop* Manifold Pressure Drop
LPM LPM
0 50 100 150 0 50 100
30 35
150 SUS (32 cSt) 2.0 150 SUS (32 cSt)
30 2.0
25
2Q 5Q 10Q
1.5 25
20
1.5
20
PSID 15 1.0 BAR PSID BAR
15 Empty Housing 1.0
Empty Housing 0.5 10
10
5 0.5
5
0 0.0 0 0.0
0 10 20 30 40 0 5 10 15 20 25 30
GPM GPM
*High Collapse Correction Factor:
“QH” Elements (2000 psid) = 1.4 times reported loss
Results typical from Multi-pass tests run per test standard ISO 16889 @ 25 gpm to 50 psid terminal - 10 mg/L BUGL.
Note: During reverse flow, ΔP is 20 psid at max. flow.
143