Page 6 - Parker Hydraulic Filter - World Pressure Filters (WPF)
P. 6

WPF Series



               WPF2 Element Performance





                                                                                  Capacity
                                                                   100
                                                                         150 SUS (32 cSt)  2Q
                                                                                         5Q            6.0
                                                                                         10Q
                                                                    80
                                                                                                       5.0

                                                                    60                                 4.0
                                                                    PSID                                  BAR

                                                                    40                                 3.0

                                                                                                       2.0
                                                                    20
                                                                                                       1.0

                                                                     0                                 0.0
                                                                       0     5    10    15    20    25
                                                                                    Grams

                        Flow vs. Pressure Drop*                            Manifold Pressure Drop

                                  LPM                                                LPM
                    0           50         100         150             0           50           100
                 30                                                  35
                      150 SUS (32 cSt)              2.0                  150 SUS (32 cSt)
                                                                     30                                 2.0
                 25
                                     2Q   5Q   10Q
                                                    1.5              25
                 20
                                                                                                        1.5
                                                                     20
                 PSID  15                           1.0  BAR        PSID                                  BAR
                                                                     15               Empty Housing     1.0
                                      Empty Housing  0.5             10
                 10

                  5                                                                                     0.5
                                                                     5

                  0                                 0.0              0                                  0.0
                    0      10     20      30     40                     0   5   10    15   20   25   30
                                  GPM                                                GPM
                         *High Collapse Correction Factor:
                   “QH” Elements (2000 psid) = 1.4 times reported loss


                  Results typical from Multi-pass tests run per test standard ISO 16889 @ 25 gpm to 50 psid terminal - 10 mg/L BUGL.

                                          Note: During reverse flow, ΔP is 20 psid at max. flow.

               143
   1   2   3   4   5   6   7   8   9   10   11