Page 142 - Parker - Parker Pneumatic
P. 142
PDE2600PNUK
Parker Pneumatic Origa OSP-P Rodless Cylinders
Order Instructions- SLIDELINE
1-4 5+6 7 8 9 10 11 12-16 17 18 19 20 21 22 23 24 25
OSPP 25 0 0 0 0 0 01100 0 0 0 0 0 0 0 0 0
Piston-Ø Stroke Piston Measuring
Mounting
16 Input in mm system
(5 digits) 0 without 0 without
25
X SFI 0.1 mm
32
Y SFI 1 mm
40
Screws Cushioning
50
0 standard 0 standard
63
1 stainless
80
Version / Piston Lubrication End cap position Guides/ Brakes/ Cover /
0 standard 0 standard 0 l+r 0° = in front Inversion Cable Channel
0 without 0 standard
1 Tandem 1 slow speed 2) 1 l+r 90° = underneath
Slideline SL 1 cable channel
2 l+r 180° = at the back 2
Ø 16-80 cable channel
Air Connection Seals 3 l+r 270° = same side Slideline with 2 two-sided
as outerband
0 standard 0 standard (NBR) 3 Activebrake SL-AB without
4 l 90° = underneath; X Cover rail
® 1)
1 on the end face 1 Viton r 0° = in front Ø 25-50
Slideline with
2 both at one end 5 l 180° = at the back; Multibrake SL-MB
(not turnable) r 0° = in front 4
Ø 25-80
3 left standard 6 l 270° = same side as
right end face outerband;
r 0° = in front
4 right standard add. Guide Carriage
left end face 7 l 0° = in front;
r 90° = underneath 0 without
A 3/2 way valve
VOE 24 V = 8 l 180° = at the back; 2 Guide Carriage Slideline SL
r 90° = underneath Ø 16-80
Ø 25,32,40, 50
9 l 270° = same side as 3 Guide Carriage Slideline
B 3/2 way valve outerband; Activebrake SL-AB
VOE 230 V~/110 V= r 90° = underneath Ø 26-50
Ø 25,32,40,50
A l 0° = in front; 4 Guide Carriage Slideline
C 3/2 way valve r 180° = at the back Multibrake SL-MB
VOE 48 V=
B l 90° = underneath; Ø 25-80
Ø 25,32,40,50 r 180° = at the back
M Guide Carriage Slideline
E 3/2 way valve C l 270° = same side as Multibrake SL-MB
VOE 110 V~ outerband; without brakefunction
Ø 25,32,40,50 r 180° = at the back Ø 25-80
D l 0° = in front;
r 270° = same side as
outerband End cap position
270°
E l 90° = underneath; (air connection) same
r 270° = same side as side as
outerband 270° 180° outerband
same at the back
F l 180° = at the back; side as end-face
r 270° = same side as outerband
outerband 180°
at the back
0°
in front
90°
end-face 0° underneath
in front
90° Cylinder
underneath
1) Viton with VOE not possible. R
®
2) “Slow speed lubrication” in combination with „Viton “ seals on demand. Cylinder (right end side)
L
(left end side)
Parker Hannifin Corporation
Origa Division - Europe
142