Page 527 - Parker - Parker Pneumatic
P. 527

PDE2600PNUK
            Parker Pneumatic                                                                 Logic Processing



           Miniature high-speed valves in stand alone,
           stackable or combined modules, incorporating
           standard logic functions. The range also includes
           timers and impulse modules.

           • Complete range
           • Stand alone, stackable or combinable modules
           • Very fast response time
           • Flexible and highly maintainable system              Operating information
           • DIN rail mounting
           • Ø 4mm connection                                     Working pressure        3 to 8 bar
                                                                  Working temperature     -15 °C to 60 °C
                                                                  Flow (Qmax)             180 l/min (PRD = 60 l/min)
                 For ATEX specific products                       ATEX approval:          CE Ex II 2 GD c 85 C
                                                                                                       o
                 contact Sales Office                             For more information see www.parker.com/euro_pneumatic
            Logic sequencer

            Step modules                      Step module                        Set of head and tail modules
                                              subbase                            and deviation      B  B
                                                                                 modules            R P A  A

                                   Order code                        Order code                         Order code
            Without sub base       PSM-A10     Subbase               PSB-A12     Head & tail set        PSE-A12
            Pneumatic output                                                     Deviation standard     PSD-A12
            Visual indication of pneumatic   PSM-A12  Additional interlock  PSV-A12
            output and manual override                                           Deviation for remote   PSD-B12
            With sub base          PSM-B12
            Wihtout manual overide
            Logic elements

            Line mounted        S  S          Combinable   S   S   S             Subbase     S   S   S   S
            elements           &   1          elements    &    1  &              mounted     1      &   &
                                                                                 elements
                                                         a  b  a  b a  b                      a   a   a   a
                              a  b  a  b
            Logic Function        Order code  Logic Function          Order code  Logic Function        Order code
            AND                   PLL-A11     AND                     PLL-B12    AND                    PLL-C10
            OR                    PLK-A11     OR                      PLK-B12    NOT inhibit standard   PLN-C10
                                              NOT                     PLN-B12    NOT inhibit threshold  PLN-D10
            Clip on Din-rail      PZM-L199    INPUT                   PLE-B12    OR                     PLK-C10
                                                                                 YES regenerated        PLJ-C10
           Logic relays                                                          3 port subbase to be ordered separately.
           Pressure switch           Amplifier relays          Memory relays             Sensor relays
           To be used with  A  B     To be used with  P  S     To be used with                          S
           3 port subbase            4 port subbase   p        4 port subbase                            a
                           a                         a
                           Order code                Order code               Order code                Order code
           With subbase   PRE-A12    With subbase   PRD-A12    With subbase   PLM-A12    With subbase   PRF-A12
           Without subbase   PRE-A10  Without subbase   PRD-A10  Without subbase   PLM-A10  Without subbase   PRF-A10
           Time delay relays                                   Subbase for logic elements and relays
           To be mounted on 3 port subbase     S               3 port and 4 port  subbases
                                              1 t  0
                                                a
           Function          Timing          Order code                                          Order code
           Output           0,1 to 3s        PRT-E10           Input module                      PZU-E12
           after timed      0,1 to 30s       PRT-A10           3 port "common input"             PZU-A12
           period           10 to 180s       PRT-B10           3 port "cascade"                  PZU-C12
                                                               4 port subbase*                   PZU-B12
           With subbase     0,1 to 30s       PRT-A12
           Output           0,1 to 3s        PRT-F10           *  For combination with memory relay and amplified relay.
           during           0,1 to 30s       PRT-C10
           timed            10 to 180s       PRT-D10