Page 533 - Parker - Parker Pneumatic
P. 533
PDE2600PNUK
Parker Pneumatic Air Saver Unit
ASV200-AA-M5 ASC500-1W-10 / ASO500-1W-10
2 x Ø4.5 (Mounting hole) ON time adjustment needle
15 15
7 6 2 1 3 5 4 7.5 7.5
External pilot port M5
(normally open) External pilot port M5
(normally closed)
Port 1 41 49
M5 11 Function indication
NC: Normally closed
13 Port 2 NO: Normally open Pulse blow
Port 3 4 Rc1/8 Frequent adjustement trimmer Indicator Port 1
M5 lamp Rc1/8
23 Max
54 18.5 OFF time adjustment needle 35 27
15.5 15.5
9 4 4 57
2 x Ø3.5
7.5 (Mounting hole) 65 7.5
8 Specified cable with connector 47.5
(Supplied separately) Connector
70 Specific 4 polar set
51 12.3 1pin: Continuous blow ON (-)
23 2 pin: COM (+)
8 3 pin: Pulse blow ON (-)
50 4 pin: Free
43.5
Port 2 M5
15
Part name Qty Material treatment
1 PLN-D10 1 Assembly Pin no. Colour
2 Flicker base 1 Aluminium alloy
3 Cover 2 Brass 1 Black
4 Needle 2 Aluminium alloy 2 Red 1000
5 Lock nut 2 Aluminium alloy 3 Yellow
6 VCC232-NB-Z12-005 1 Assembly 4 (Free) *Cable with specific connector “ASC-D24-CL10”
(AWG26 ASC/ASO in common)
7 Plug R1/4 1 Black oxide finish
8 BC-03-M3 2 Stainless
9 TN-3.2 8cm Polyamide resin
ASV2000 ASV5000 30 M5 Pilot air supply port
Port 4
Port 2 Rc3/8 (Plug) 25 25 Rc3/8 Pilot air supply port M5
6.5
60
50
Plug 38.5
54 68 82
1
30 30 5
3 x Ø7 48 81 Threshold element
(Mounting hole) Max 15.5
17
50
64.5 2 x Ø5.5
90.5 Max 15.5 OFF time
30 29.5 adjustment needle
Port 3 Rc3/8 (Plug) 15 20 15.5 Plug
Port 1 Rc3/8 (Plug) Port 1
15 15.5 Rc1/2
Port 5 Rc3/8 (Plug) Rc1/2
OFF time adjustment needle
ON time adjustment needle
32 46
16 92
16 32
Plug
Threshold element 22.5 Exhaust port
Note: Be careful about mounting direction (Port 3, 5)
Rc3/8 Plug
Parker Hannifin Corporation
Pneumatic Division - Europe
533