Page 558 - Parker - Parker Pneumatic
P. 558
PDE2600PNUK
Parker Pneumatic Fluid Controls
Piped Valves - G1/4" Series
Solenoid Operated Versions
P33 Versions with 32-37-40 mm Coil
Port Orifice Q N Admissible Maximum Seat Reference Consumption Weight Elect. Dim.
size differential admissible fluid disc number Power (g) Group Ref.
pressure (bar) temperature (ºC) (Watt)
maximum minimum = 0ºC
G mm l/min min DC= AC~ Air & Neutral Valve Housing Coil DC AC
gases
4 2
5/2 Solenoid operated 14
Combined spring & air return (monostable) 5 13
1/4 7 1250 2.5 10 10 50 NBR 341P33 2995 481865 9 8 470 2 20
1/4 7 1250 2.5 10 10 50 NBR 341P33 2995 495870 9 8 490 2 -
1/4 7 1250 2.5 10 10 50 NBR 341P33 - 495905 8 8 810 2 -
14 17
5/2 Solenoid operated and return (bistable) 5 13
1/4 7 1250 2.5 10 10 50 NBR 347P33 2995 481865 9 8 620 2 21
1/4 7 1250 2.5 10 10 50 NBR 347P33 2995 495870 9 8 640 2 -
1/4 7 1250 2.5 10 10 50 NBR 347P33 - 495905 8 8 960 2 -
Dimensions Reference 20 Dimensions Reference 21
Parker Hannifin Corporation
Pneumatic Division - Europe
558