Page 15 - Gast Linear Catalog
P. 15
DDL30, DDL40, DDL60, DDL80 to
Medium Capacity 120
LPM
DDL30
5.4 psi max. pressure (.37 bar) 54 LPM open flow (60 Hz)
5.1 psi max. pressure (.35 bar) 65 LPM open flow (50 Hz)
DDL40
5.9 psi max. pressure (.41 bar) 65 LPM open flow (60 Hz)
5.8 psi max. pressure (.40 bar) 76 LPM open flow (50 Hz)
DDL60
6.3 psi max. pressure (.43 bar) 79 LPM open flow (60 Hz)
6.1 psi max. pressure (.42 bar) 102 LPM open flow (50 Hz)
DDL80
7.0 psi max. pressure (.48 bar) 120 LPM open flow (60 Hz)
7.0 psi max. pressure (.48 bar) 111 LPM open flow (50 Hz)
Product Dimensions 0.75
(inches, mm) 8.15 19.0 7.01
207.0 178.0
8.28
1.07 210.4
27.2
0.71 DIA
18.0
1.77
3.94 3.94 45.0
100.0 100.0
Product Specifications • All 101 models include a 6 ft. cord/plug
assembly; 801 models include a 1.8 metre cord
Model Operating Voltage Typical Operating Typical Operating Sound Level Net Wt. with pigtails (not shown in photo or drawing)
Number Frequency (Hz) Power (W) Pressure (psi/bar) dB(a) lb kg
DDL30-101 120-60 43 1.85 / 0.13 40 12 5.4 • Additional plug configurations available
DDL30-801 230-50 32 1.85 / 0.13 40 12 5.4 • In compliance with the European
DDL40-101 120-60 45 1.85 / 0.13 41 12 5.4 Community’s Machinery Directive
DDL40-801 230-50 41 1.85 / 0.13 38 12 5.4 • UL listed to UL 1450 air compressor/vacuum
DDL60-101 120-60 64 2.13 / 0.15 50 13 6.3
DDL60-801 230-50 64 2.13 / 0.15 40 13 6.3 pump and Canadian Standard C22.2 No 68-92
DDL80-101 120-60 84 2.13 / 0.15 52 13 6.3 • Quiet operation
DDL80-801 230-50 91 2.13 / 0.15 40 13 6.3 • Drop into existing system
• Aluminum housing for better ventilation
Product Performance 50 HZ 60 HZ
120 120
4.0 4.0
100 DDL80 3.0 100 DDL80
Free Air Flow (CFM) 2.0 Free Air Flow (lpm) 60 DDL60 Free Air Flow (CFM) 2.0 Free Air Flow (lpm) 60 DDL60
3.0
80
80
40
40
1.0
20 DDL40 1.0 20 DDL40
DDL30 DDL30
0 0 0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
psig psig
0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0.4 0.5
Metric(bar) Metric(bar)
www.gastmfg.com Gast Linear Compressors and Vacuum Pumps 15