P. 6
®
4300 Catalog Ferulok Flareless Reference
Ferulok Flareless Tube Ends Return
To
Catalog
Ferulok Male Ferulok Female Swivel End Ferulok Tube End
Stud Tube End Assembly
Ferulok Shape Ferulok Straight
Bulkhead Bulkhead
Max Bulkhead
Allowance Bulkhead Thickness Across Corners
Tube Bulhkead Swivel Male Pilot Thread Tube Swivel
Nut Locknut Nut Max Tube Nut Turn Length Length - Length - Locknut Pilot Engage- Nut Nut
Thread Hex Hex Hex Drill Assembled Tube Back Shapes Straights Shapes Thickness Dia Straights Shapes ment Hex Hex
SAE Tube
Dash O.D. T C C2 C3 D F K L K2 L1 L2 R W 1) M1 M2 TE U1 U2
Size (in.) UN/UNF (in.) (in.) (in.) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in (in) (in)
2 1/8 5/16-24 3/8 9/16 7/16 0.093 0.31 0.19 0.375 0.09 1.02 0.83 0.22 0.31 0.28 0.38 0.22 0.22 0.25
3 3/16 3/8-24 7/16 5/8 1/2 0.125 0.34 0.24 0.422 0.09 1.06 0.88 0.22 0.37 0.28 0.38 0.25 0.25 0.29
4 1/4 7/16-20 9/16 11/16 9/16 0.203 0.42 0.24 0.453 0.09 1.12 0.94 0.28 0.44 0.38 0.28 0.29 0.33 0.33
5 5/16 1/2-20 5/8 3/4 5/8 0.234 0.42 0.26 0.453 0.09 1.12 0.94 0.28 0.50 0.28 0.38 0.31 0.36 0.36
6 3/8 9/16-18 11/16 13/16 11/16 0.281 0.47 0.26 0.469 0.09 1.17 0.98 0.27 0.56 0.40 0.31 0.34 0.40 0.40
8 1/2 3/4-16 7/8 1 7/8 0.422 0.50 0.31 0.562 0.13 1.31 1.12 0.31 0.75 0.40 0.31 0.32 0.51 0.51
10 5/8 7/8-14 1 1 1/8 1 0.500 0.53 0.36 0.625 0.13 1.45 1.27 0.36 0.88 0.44 0.38 0.37 0.58 0.59
12 3/4 1 1/16-12 1 1/4 1 3/8 1 1/4 0.656 0.56 0.36 0.688 0.13 1.56 1.38 0.41 1.06 0.44 0.38 0.42 0.72 0.73
14 7/8 1 3/16-12 1 3/8 1 1/2 1 3/8 0.719 0.53 0.36 0.688 0.13 1.56 1.38 0.41 1.19 0.44 0.38 0.34 0.79 0.79
16 1 1 5/16-12 1 1/2 1 5/8 1 1/2 0.875 0.66 0.42 0.688 0.13 1.56 1.38 0.41 1.31 0.44 0.38 0.32 0.87 0.88
20 1 1/4 1 5/8-12 2 1 7/8 2 1.094 0.72 0.42 0.688 0.13 1.56 1.38 0.41 1.62 0.44 0.38 0.33 1.15 1.17
24 1 1/2 1 7/8-12 2 1/4 2 1/8 2 1/4 1.344 0.72 0.49 0.688 0.13 1.56 1.38 0.41 1.87 0.44 0.38 0.34 1.30 1.29
32 2 2 1/2-12 2 7/8 2 3/4 2 7/8 1.813 0.84 0.49 0.688 0.13 1.77 1.58 0.41 2.50 0.63 0.56 0.34 1.66 1.64
1) Recommended clearance hole +0.015 over W dia.
Note: For port and stud end dimensions reference Section F: Pipe Fittings and Port Adapters.
Dimensions and pressures for reference only, subject to change.
C6 Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
http://www.parker.com/tfd