Page 4 - Proportion-Air - GP1/GP2
P. 4

Example Part Number :  GP        2     B     N     E     E    Z           P  500  PS       G     1    O2  TF

        YOUR PART NUMBER :  GP

                      Section  ——>   1        2     3     4    5     6     7     8     9  10  11  12            13





         1  Type                                                  8  Full Scale Pressure Type
           1    Single Loop                                         N    100% Pressure Ends Below Atmosphere

           2    Double Loop (external feedback, Option 3D)           P    100% Pressure Ends Above Atmosphere
                                                                     Z    100% Pressure Ends at Zero
         2  Manifold Material

           B    Brass (Standard)                                  9  Full Scale Pressure
           S    303 Stainless Steel                                    This is an example. Your number will be the top of
                                                                  650
                                                                       your desired pressure range.

         3  Thread Type
                                                                 10  Pressure Unit
           N    NPT (Standard)
           P    BSPP                                                PS    PSI                       Inches Hg    IH
                                                                   MB    Millibars                Inches H2O    IW
         4  Input Signal Range                                      BR    Bar                       Mm H2O    MW
                                                                    KP    Kilopascal            Kilograms cm²    KG
           E    0 to 10 Vdc                0 to 5 Vdc    K
                                                                   MP    Megapascal                      Torr    TR
            I    4 to 20 mADC              1 to 5 Vdc    V
                                                                   MH    mm Hg               Centimeters H2O    CW

         5  Monitor Signal Range
                                                                 11  Pressure Unit of Measure
           X    No Monitor                 0 to 5 Vdc    K
                                                                     A    Absolute Pressure
           E    0 to 10 Vdc                1 to 5 Vdc    V
                                                                    G    Gage Pressure
           S    4 to 20 mADC (Sourcing)

                                                                 12  Valve Type
         6  Zero Offset
                                                                     1    0.012”
           N    0% Pressure Starts Below Atmosphere                                         Please Consult Factory for Valve
                                                                     2    1/32”             Sizing Assistance
           P    0% Pressure Starts Above Atmosphere
                                                                     3    3/64”
           Z    0% Pressure Starts at Zero (Typical)

                                                                 13  Popular Options
         7  Zero Offset Pressure
                                                                    TF    Test & Calibrate Unit Under Flow
              This is an example. Your number will be the bottom
        14.7   of your desired pressure range. Most often your     O2    Oxygen Cleaned
              number will be ‘0’.
                                                                   O3    Oxygen Cleaned for Non-Oxygen Use
                                                                   HR    Use High Resolution PCB (Valve Type ‘1’ Only)

                                                                   Please call if you need assistance with your application




                                                                                                                 BRGP0607E
   1   2   3   4