Description and Handling
1 218 Series
80
Terminating stranded conductors in confined spaces Terminating 0.75 mm / 18 AWG conductors is possible; Testing directly on the clamping spring.
2
requires a great deal of patience, unless you use the new however insulation diameter allows only every other
218 Series terminal strips. The clamping units of these clamping unit to be terminated with this conductor size.
strips can be held open during termination process via
integrated locking slide.
Incorrect — Do not operate the locking slides from the
back.
Conductor termination: To momentarily open clamping
unit, use screwdriver and then insert stripped conductor.
To open clamping unit for extended period, move locking
slide toward conductor entry hole. Then fully insert
stripped conductor and move locking slide back to original
position (also possible to perform with fingernail).
Insulating housings available in different colors. Marking via self-adhesive strips or ... ... factory direct printing.
CAGE CLAMP termi-
®
nates the following
copper conductors:* fine-stranded,
also with tinned
solid stranded single strands
* For aluminum conductors, see notes in Section 13.