Set-up and Control                  General Motion Control

          Software                            Tuning/Control & Set Up
                                              • Stroke
                      TM
          This Windows  based software        • Stroke Speed
          provides you with a simple way to   • Current Limit
          select all aspects of confi guration and   • Acceleration
          control  required to set up and oper-  • Power on Delay
          ate the EXP-24 Positioner.  Easy to use   • Tuning Parameters
          tabbed pages provide access to input   I/O
          all of the parameters necessary for   • Digital I/O Confi guration
          the confi guration of either your valve   • Analog Signal Confi guration
          control or general motion application.   • Input and Output Function Control
          The software uses a hierarchical ar-  • Analog Calibration
          rangement of Application Files and   Motion Setup
           Drive Files.  The Application Files de-  • Move Distance
           termine what is displayed and how it   • Jogging
           is displayed on the screen.  The Drive   • Homing
           Files contain the information about   • Operator Control Panel
           the parameters that are displayed,   Diagnostics
           such as name, min and max value, de-  • Real time monitoring
           fault value and most importantly the   • Following error
           actual value as saved or uploaded.  • Position error
           Valve Control                      • Input and output status
           Set Up                         I/O                      • Communication diagnostics
                                              • Multi-channel oscilloscope
           • Stroke                                • Analog I/O
                                              • Loss of signal monitoring
           • Stroke Speed                  • Discrete I/O
           • Valve Seat Cut-off
           • Current Limit
           • Homing
           Diagnostics
           • Real Time Monitoring
           • Oscilloscope
                            '5$,1   9(17
                                        723        ;     137 7+58
                  $&78$725   02725
                    32:(5 3257                      $&78$725   02725
                                                     )(('%$&. 3257
                                                                    3/& , 2
                                                                     32576
                                        )5217             5,*+7                  %$&.
                            ;
                       &29(5 6&5(:6
                                                                  ;     137 7+58

                                                                                        $

                                                               *5281' /2&$7,21


                                        %27720
                                                                               5



                                               '5$,1   9(17                                                              Exlar Corporation
                                                                                                          18400 West 77th Street
                                                                                                      Chanhassen, MN 55317
                                                                  '(7$,/ $
                                                                                                     Phone 952-500-6200
                                                                                                       Fax 952-368-4877
                                                                                                        www.exlar.com
                                                                                                            PN: 47294