Page 6 - Wieland - Podis LED
P. 6
®
podis led
LED luminaires 70 – 250 V AC
podis led Luminaire Description Type Order No
FCS 70-250 V AC 5W podis led Luminaire FCS 70-250 V AC 5W 83.241.0020.0
podis led FCS 70-250 V AC 5W; energy saving Technical data
LED-luminaire pluggable on flat cable outlet Min. nominal voltage 70 V AC
(Art.-No. 75.015.5153.1); for harsh industrial Max. nominal voltage 250V AC
environments (e.g. wind turbines) and emergency Connected phase L1
light acc. EN 60598-2-22; orientation Lamp LED
independent mounting; 70…250 V AC; 5 W; typ. Operation mode Continuous
360 lm; daytime white, 6500 K; integrated reverse Lamp output 5W
polarity-, overload- and shortage protection; IP65 Fuse Device fuse
encapsulation; operating temperature Reverse polarity protection yes
-40…+55 °C (-40…130 °F); EN 60598-1 Emergency light marking Z 1 ***
Light colour 6500 K
Ambient temperature Ta min. -40 °C
Ambient temperature Ta max. 55 °C
Storage temperature / transport min. -40 °C
Storage temperature / transport max. 70 °C
Standards DIN EN 60598-1, DIN EN 60598-2-22
Installation type Locked plug connection
Switching type Maintained / non-maintained
Protection class (IP) IP65
Power supply podis con plug connection
W x H x D (mm) 124 x 104 x 136
Approvals (pending) a
podis led Luminaire Description Type Order No
RST 70-250V AC 5W podis led Luminaire RST 70-250 V AC 5W 83.241.0040.0
podis led RST 70-250 V AC 5W; energy saving Technical data
LED-luminaire pluggable by round Min. nominal voltage 70 V AC
connectors RST 20i3, opposite configuration, Max. nominal voltage 250V AC
black coding; for harsh industrial environments Lamp LED
(e.g. wind turbines) and emergency light acc. Operation mode Continuous
EN 60598-2-22; orientation independent Lamp output 5W
mounting; 70…250 V AC; 5 W; typ. 360 lm; Fuse Device fuse
daytime white, 6500 K; integrated reverse Reverse polarity protection yes
polarity-, overload- and shortage protection; Emergency light marking Z 1 ***
IP66/68 encapsulation; operating temperature Light colour 6500 K
-40…+ 55 °C (-40…130 °F); EN 60598-1 Ambient temperature Ta min. -40 °C
Ambient temperature Ta max. 55 °C
Storage temperature / transport min. -40 °C
Storage temperature / transport max. 70 °C
Standards DIN EN 60598-1, DIN EN 60598-2-22
Installation type Wall-mounted
Switching type Maintained / non-maintained
Protection class (IP) IP65
Power supply RST 20i3 black plug connection
W x H x D (mm) 124 x 104 x 96
Approvals (pending) a
Technical Data
Characteristics, Maximum Ratings Value
Operating current 24 VDC 0.2 A
Operating current 110 / 230 VAC 0.09 / 0.055 A
Fuse, resetting 0.5 A / 60 V
Luminous flux 360 lm 1)
Reverse polarity protection Diode in conjunction with fuse
Life cycle > 50.000 hrs
Cooling Free convection
Weight (approx.) 320 g
Emergency light operation DIN EN 60598-1, DIN EN 60598-2-22
Noise emission acc. to DIN EN 55015: 2009 -11
EMC DIN EN 61547: 2010-03
Klima DIN EN 60068-2-30: 2006-06
CE mark EMC directive
Rohs compliant yes
Corrosion protection class C4
Packing unit 1 pc.
1) at 20°C ambient temperature