Page 31 - Linde- HPR-02 Model code options
P. 31
14. Mount – Through Drive
HPR – XXX – X – X – X – XXXX – X – X – X – X – XXXX – X – X – X – X X – X – 2 – X
(ex. HPR – 135 – S – R – I – E1L – 1 – H – D – D – M250 – X – X – X – C C – C – 2 – X)
All HPR-02 pumps are configured with an SAE A, 2-Bolt Mount in the port plate housing. The
HPR-02 pumps can be configured with many different PTO options:
(1) The pump may have just a PTO flange and cover plate
(2) The pump may have an ancillary gear pump affixed to it with a through drive
(3) The pump may have an ancillary gear pump affixed to it without a through drive
(4) The pump may have another Linde pump affixed to it
The only PTO option that you could check is option “1”. To verify the PTO mount size, the
cover plate on the PTO flange should be removed and the actual PTO flange pilot diameter
should be measured to ensure it is the correct size (i.e. SAE A, B, C, etc.).
The following slides are examples of the various PTO flange options available for the HPR-02
pumps. These are examples and are not all inclusive.
11/16/2015 31