Page 22 - Parker - P1/PD series medium duty axial piston pumps
P. 22

HY28-2665-01/P1/EN                                      Medium Duty Axial Piston Pumps
            P1 Performance Data                                     P1/PD Series


            P1 Series Typical Noise Characteristics
            (These are anechoic sound pressure readings)

                         P1 060 Mobile Pump Typical Sound Level              P1 075 Mobile Pump Typical Sound Level
                    anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature  anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
              90                                                  90
                 2400 rpm                                            2300 rpm
                 1800 rpm                                            1800 rpm
                                                                  85
                 1500 rpm                                            1500 rpm
             Sound pressure level dB(A)  80                      Sound pressure level dB(A)  80
              85
                                                                     1200 rpm
                 1200 rpm

                                                                  75
              75
                                                                  70

                             solid lines are for maximum displacement and dashed lines are for zero flow  solid lines are for maximum displacement and dashed lines are for zero flow
              70                                                  65
               50       100      150      200      250      300    0     50     100   150    200   250   300    350
                              Pump outlet pressure (bar)                          Pump outlet pressure (bar)

                         P1 100 Mobile Pump Typical Sound Level              P1 140 Mobile Pump Typical Sound Level
                    anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature  anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
              90                                                  90
                 2100 rpm
                                solid lines are for maximum displacement and dashed lines are for zero flow  2000 rpm
                 1800 rpm
                                                                     1800 rpm
              85  1500 rpm                                        85  1500 rpm
             Sound pressure level dB(A)   80 75  1000 rpm        Sound pressure level  dB(A)  80  1000 rpm
                 1200 rpm
                                                                     1200 rpm

                                                                  75


              70                                                  70
                                                                                solid lines are for maximum displacement and dashed lines are for zero flow
              65                                                  65
               0     50    100    150    200   250    300   350    0     50     100   150    200   250   300    350
                              Pump outlet pressure (bar)                          Pump outlet pressure  (bar)

























                                                                                              Parker Hannifin Corporation
                                                                                              Hydraulic Pump Division
                                                             20                               Marysville, Ohio USA