Page 37 - Parker - P1/PD series medium duty axial piston pumps
P. 37
HY28-2665-01/P1/EN Medium Duty Axial Piston Pumps
Dimensional Data P1/PD Series
Pump Installation - P1/PD 018 "D3"
Case Drain Port
End Port 164.2
“L” Control Option 67
19
"BG" Gage
Outlet Port
"D1"
Case Drain Port
24
40.6
38.6
To Load Sense 61.2
Port "X"
93.2
214 Maximum
For Shaft and Flange
Dimensions see page 34
Press. Compensatator
Adj. Screw
Load Sense
Adj. Screw
CW Control 107.7
Location
CW Rotation 84.5 100.1
Arrow "D2"
67.5 Case Drain Port
64.5 1.2
Plug
"X" Load
Sense Port
116.3
109.3
76.1
51.0
53.5
77
118.8 74
111.8
12.5
9.5
CCW Control
Location Nameplate
CCW Rotation
Arrow
P1/PD 018 Port Sizes
2X
23.0 "B" Outlet Port SAE ISO BSP
(To Drain Ports)
2X "A" Inlet SAE-16 B M33x2 A -
18°
2X "B" Outlet SAE-12 B M27x2 A -
70.9
(To Drain Ports)
"BG" SAE-4 B M12x1 5 A 1/4" C
D1 D2 D3 SAE-6 B M16x1 5 A 3/8" C
"X" SAE-4 B M12x1 5 A 1/4" C
Note A: Metric o-ring boss port conforms to ISO 6149-1
Note B: Inch o-ring port conforms to SAE J514
Note C: BSP port conforms to ISO 228-1
"A" Inlet Port
30.5 30.5
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio USA 35