Page 45 - Parker - P1/PD series medium duty axial piston pumps
P. 45
HY28-2665-01/P1/EN Medium Duty Axial Piston Pumps
Dimensional Data P1/PD Series
Pump Installation - P1/PD 045
2X
End Port 188.2
84.7
“L” Control Option 68.5
To Load Sense
"X" Port
"BG" Gage
Outlet Port
SAE J514 Straght
Thread O-Ring Port
7/16-20 UNF-2B
(SAE-4)
38.0
Press. Compensating 46.0 28.7
Adj. Screw 90.2
Load Sense 122.2
Adj. Screws 3X
Case Drain Ports
SAE J514 Straight
120.7 Thread O-Ring Port
"X" Load Senseport 7/8-14 UNF-2B
SAE J514 Straight 97.5 74.2 (SAE - 10)
Thread O-Ring Port 3.0 106.7
7/16-20 UNF - 2b 51.6 Plug
SAE - 4)
CCW Control
Location
CCW Rotaiton
Arrow 92.2
116.8
51.0 51.6
45°
101.60
Ø
101.55
SAE J744 - June 96
101-2 (B)
92.3
Sta
9.5 Optional Threa
2X 1 7/8-12 UN-2
Ø14.4
1/
Nameplate
ad O Ring Port
14 UNF-2B
E - 10) 2X 33.0
To Drain Ports 2X 26.2
18° 14.1
2X 85.5 P1/PD 045 Port Sizes
To Drain Ports
SAE
26.2
SAE 4 Bolt ISO BSP
Threaded
35.0 42.5
"A" Inlet 38mm Code 61 D SAE-24 38mm DN51 E -
52.4
70.0 "B" Outlet 25mm Code 61 SAE-16 25mm DN25 E -
37.5
"BG" SAE-4 B M12x1.5 A 1/4" C
D1 D2 D3 SAE-10 B M22x1.5 A 1/2" C
"A" Inlet Port
SAE J518 Code 61
Standard Pressure Series "X"
1-1/2 (-40) 4X SAE-4 B M12x1.5 A 1/4" C
Optional Threaded Port: SAE 3/8-16
1 7/8-12 UN-2B UNC-2B 17
4X 17.9 Note A: Metric o-ring boss port conforms to ISO 6149-1
1/2-13 UNC-2B in. 20 35.8 Note B: Inch o-ring port conforms to SAE J514
Note C: BSPP port conforms to ISO 228-1
"B" Outlet Port
SAE J518 Code 61 Note D: Inch 4-bolt flange port conforms to SAE J518
Standard Pressure Series
1 in. (-16) Note E: Metric 4-bolt flange port conforms to ISO 6162
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio USA 43