Page 106 - Parker - Pressure Control Valves
P. 106
Catalog HY15-3502/US D.A., N.C. Sequence Valve (Ext. Pilot & Drain)
Technical Information Series B04H4
CV
Dimensions Millimeters (Inches)
Check Valves
22 5 AF Hex socket
(0.87) max
SH
17 AF Hex. Shuttle Valves
12 Nm
(9 lb. ft.)
Torque LM
59 26 AF Hex. Load/Motor Controls
(2.32) 50 Nm
(37 lb. ft.)
Torque
FC
Flow Controls
7/8" - 14 UNF
PC
(4)
Pressure Controls
62.5
(2.46)
(3)
(2) LE
Logic
(1) Elements
DC
Directional
Ordering Information Controls
B04H4 MV
10 Size Pilot Adjustment Pilot Seals Sealed Body Port
D.A. Sequence Valve Pressure Style Switching Pilot Material Size Manual Valves
(External Pilot Adjustment Pressure
and Drain) Range
SV
Code Pilot Pressure Adjustment Range Code Seals / Kit No. Code Body Material
E 2 - 80 Bar (30 - 1160 PSI) N Nitrile, Buna-N (Std.) / Omit Steel Solenoid Valves
G 2 - 166 Bar (30 - 2400 PSI) (SK30506N-1) A Aluminum
J 40 - 240 Bar (580 - 3500 PSI) V Fluorocarbon / PV
(SK30506V-1)
Code Port Size Body Part No.
Code Adjustment Style / Kit No. Omit Cartridge Only Proportional Valves
Code Sealed Pilot
Z Screw Adjust (Std.) 6P 3/8″ NTPF (B10-4-*6P)
Omit Omit if not required
W Knob Adjust 6T SAE-6 (B10-4-*6T) CE
S Sealed Pilot 8T SAE-8 (B10-4-*8T)
T Tamper Resistant Cap (TC1130)
6B 3/8″ BSPG (B10-4-6B)†
* Add “A” for aluminum, omit for steel. Coils & Electronics
Code Pilot Switching Pressure † Steel bodies only
Omit Omit for Standard Setting BC
B04H4E Standard Setting:
40 Bar (580 PSI) @ 5 LPM (1.3 GPM)
B04H4G Standard Setting: Bodies & Cavities
80 Bar (1160 PSI) @ 5 LPM (1.3 GPM)
B04H4J Standard Setting: TD
120 Bar (1750 PSI) @ 5 LPM (1.3 GPM)
Technical Data
Specify setting if required
PC104 Parker Hannifin Corporation
Hydraulic Cartridge Systems