Page 27 - Parker - Pressure Control Valves
P. 27
Catalog HY15-3502/US Direct Acting Relief Valve
Technical Information Series A04C2
CV
General Description
Direct Acting Spool-Type Relief Valve. For additional
information see Technical Tips on pages PC1-PC6.
Valves
Check
SH
Features
• High flow capacity
Valves
Shuttle
LM • Fast response with good stability
• Low pressure setting
• Full 420 Bar 6000 PSI tank line back pressure
• Hardened working parts for maximum durability
Load/Motor
Controls
FC
• Adjustable, preset and tamperproof versions available
• All external parts zinc plated (1) (2)
Flow
Controls
PC
(2)
(1)
Pressure
Controls
LE Specifications Performance Curve
(Pressure rise through cartridge only)
Rated Flow 200 LPM (53 GPM)
Flow vs. Inlet Pressure
Elements
Logic
Maximum Inlet D - 2-50 Bar (29-725 PSI) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
DC Pressure F - 2-100 Bar (29-1450 PSI) 2900 200
Maximum 420 Bar (6000 PSI)
Pressure Setting 2175 150
Pressure Drop
Directional
Controls
MV Maximum Tank 420 Bar (6000 PSI) A04C2F A04C2F
Pressure 1450 100
Leakage at 25 ml/min. A04C2D
150 SSU (32 cSt) @ 50 Bar (725 PSI) 725 50 A04C2D
Manual
Valves
SV
Cartridge Material All parts steel. All operating
parts hardened steel. BASIC VALVE PRESSURE DROP
0
LPM 50 100 150 200
0
Solenoid
Valves
Operating Temp. -40°C to +93.3°C (Nitrile) GPM 13.2 26.4 39.6 52.8
PV Range/Seals (-40°F to +200°F) Flow (Q)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Fluid Mineral-based or synthetic with
Valves
Proportional
CE Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Electronics
Coils &
BC
Approx. Weight 0.28 kg (0.62 lbs.)
Cavity C10-2
Bodies &
(See BC Section for more details)
Cavities
TD
Form Tool Rougher None
Finisher NFT10-2F
Data
Technical
PC25 Parker Hannifin Corporation
Hydraulic Cartridge Systems