Page 34 - Parker - Pressure Control Valves
P. 34
Catalog HY15-3502/US Direct Acting Relief Valve With Check
Technical Information Series RDCH103
CV
Dimensions Millimeters (Inches)
Check Valves
CYL CV1 SH
10.4 Shuttle
18.3 15.9 (.41) Valves
(.72) (.63)
CV1
LM
Ø 7.1 (.28) Thru
Mounting Hole
(2) Holes Load/Motor Controls
41.4 36.1
RV1 (1.63) Screw Option Shown (1.42) FC
63.5 19.1
(2.50) (.75)
Flow
RV1 Controls
PC
22.2
15.9 78.4 (.88)
(.63) (3.09) 31.8 38.1 Pressure Controls
Max. (1.25) (1.50)
LE
0.8
(.03) 51.1 15.9
Max. (2.01) (.62) Elements
Logic
31.8
(1.25) DC
V
76.2 Directional Controls
THIRD-ANGLE (3.00)
PROJECTION
MV
Manual Valves
Ordering Information
SV
RDCH103
Solenoid Valves
10 Size Adjustment Pressure Optional Check Valve Seals Port
Direct Acting Relief Valve Style Range Pressure Cracking Size
With Reverse Flow Check Setting Pressure
PV
Code Adjustment Style / Kit No. Code Pressure Range Optional Pressure Setting Code Seals / Kit No. Proportional
F Fixed style, preset at factory. 10 6.9 - 69 Bar (100 - 1000 PSI) Pressure ÷ 10 Omit “D”-Ring / (SK10-2) Valves
K Knob Adjust (717784-10) Standard Setting: i.e. 235 = 2350 PSI N Nitrile / (SK10-2N)
34.5 Bar (500 PSI) (Omit if standard setting
S Screw Adjust @ .95 LPM (.25 GPM) is used) V Fluorocarbon / (SK10-2V) CE
T Tamper Resistant Cap 20 34.5 - 138 Bar (500 - 2000 PSI) Setting Range:
(717943) Standard Setting: 100 to 5000 PSI Code Port Size Part No. Electronics
69 Bar (1000 PSI) All settings at 8T SAE-8 830313 Coils &
@ .95 LPM (.25 GPM) .95 LPM (.25 GPM) Individual body requires 1 SAE 5 plug.
30 34.5 - 207 Bar (500 - 3000 PSI) Part number 5 HP50N-S. BC
Standard Setting: Code Cracking Pressure
103.5 Bar (1500 PSI) Omit 0.3 Bar (5 PSI)
@ .95 LPM (.25 GPM) P20 1.4 Bar (20 PSI) Bodies & Cavities
50 34.5 - 345 Bar (500 - 5000 PSI) P50 3.5 Bar (50 PSI)
Standard Setting: TD
172.4 Bar (2500 PSI) P65 4.5 Bar (65 PSI)
Technical Data
@ .95 LPM (.25 GPM) P100 6.9 Bar (100 PSI)
PC32 Parker Hannifin Corporation
Hydraulic Cartridge Systems