Page 73 - Parker - Pressure Control Valves
P. 73
Catalog HY15-3502/US Direct Acting, Unloading Pilot Relief Valve
Technical Information Series M04A4J
CV
General Description
Direct Acting, Spool-Type, Unloading Relief Valve with
Internal Pilot. For additional information see Technical
Valves
Check
SH Tips on pages PC1-PC6.
Features
Valves
Shuttle
LM • Use to unload a load sense pump in an accumulator
circuit
• One size unloading valve for all flow size applications
• Hardened working parts for maximum durability (4) (2)
Controls
Load/Motor
FC • Adjustable and tamperproof versions available
• All external parts zinc plated (4)
(3)
Controls
Flow
(3) (1)
PC
(2)
(1)
Pressure
Controls
LE Specifications Performance Curve
Accumulator Circuit
Rated Flow 2 LPM (0.53 GPM)
Unload ACCUMULATOR PRESSURE
Elements
Maximum Inlet 420 Bar (6000 PSI) Pressure
Logic
DC Pressure SCAN
Maximum 200 Bar (2900 PSI) Reload
Pressure
Pressure Setting
Controls
Directional
MV Maximum Tank 420 Bar (6000 PSI) Pressure
Pressure
Leakage at 25 ml/min.
Valves
150 SSU (32 cSt) @ 100 Bar (1450 PSI)
Manual
SV
PUMP PRESSURE
Cartridge Material All parts steel. All operating
Time
parts hardened steel.
Solenoid
Valves
Operating Temp. -40°C to +93.3°C (Nitrile)
PV Range/Seals (-40°F to +200°F) Application
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Proportional
Valves
Fluid Mineral-based or synthetic with
CE Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Electronics
Coils &
BC
Approx. Weight 0.33 kg (0.73 lbs.)
Cavity C10-4
Cavities
(See BC Section for more details)
Bodies &
TD
Form Tool Rougher None
Finisher
Technical
Data
PC71 Parker Hannifin Corporation
Hydraulic Cartridge Systems