Fulfl o SWC Filter Cartridges
SWC
SPECIFICATIONS Length Factors SWC Flow Factors (psid/gpm @ cks)
Materials of Construction
• Polypropylene Length Length Rating Cotton All
• Cotton (in) Factor (μm) Synthetics
10 1.0 1 2.00 0.75
Maximum Recommended 3 0.63 0.33
Operating Conditions 20 2.0
• Temperature: 30 3.0 5 0.36 0.24
- Polypropylene: 40 4.0 10 0.19 0.14
200°F (93°C) with tinned steel or 15 0.16 0.12
stainless steel cores; 120°F (49°C) with Flow Rate and Pressure Drop Formulas 20 0.11 0.09
polypropylene cores Flow Rate (gpm) = Clean ΔP x Length Factor
- Cotton: Viscosity x Flow Factor 25 0.10 0.08
250°F (121°C) with tinned steel or Clean ΔP = Flow Rate x Viscosity x Flow Factor 30 0.09 0.07
stainless steel cores;120°F (49°C) with Length Factor 50 0.07 0.06
polypropylene cores
Notes: 75 0.06 0.05
• Change Out ΔP: 30psi (2.1bar) 1. Clean ΔP ispsi differential at start. 100 0.06 0.05
2. Viscosity is centistokes. Use Conversion Tables for other units.
• ΔP @ Ambient Temperature: 3. Flow Factor is ΔP/GPM at 1cks for 10 in. (or single).
60psi (4.1bar) 4. Length Factors convert fl ow or ΔP from 10 in. (single length) to
required cartridge length.
• Flow Rate: 5gpm (18.9 lpm) per
10 in. length
Nominal Removal Ratings
• 90% effi ciency from 1μm to 100μm
Dimensions
3
• 1 in. ID x 2- ⁄ 8 in. OD
10, 20, 30 and 40 in. lengths
Ordering Information
SWC –
Cartridge Code Micron Rating (Nominal) Fiber Type Core Material Core Extender Packaging Options
Code Description Code Micron Code Material Code Description Code Description Code Material
String Wound 1 1.0 Cotton None Tinned Steel None No Extender Individual
SWC C Z
Cartridge (FDA Grade) Poly Bag
3 3.0 A Polypropylene Std. Open End/
Polypropylene OB Polypro Spring TIS Tissue Wrap
5 5.0 M G 304 Stainless Steel
(FDA grade) Closed End
10 10.0 Polypropylene S 316 Stainless Steel Snap-in
T XA
15 15.0 (Industrial grade) (Polypropylene)
20 20.0 U Cotton, natural Extended Core
XB Open End/Polypro
25 25.0 WC White cotton Spring Closed End
30 30.0
Nominal Length Integral (Tinned
50 50.0 XC Steel 304SS or
Code Inches 316SS)
75 75.0
9-4 9- 7 ⁄8
100 100.0 Core Cover Material
10 10
Code Description
19-4 19-½
None No Cover
20 20
V Non-woven Polyester
29-4 29-¼
Y Polypropylene
30 30- 3 ⁄16
39-4 39
40 40- 3 ⁄16
Specifi cations are subject to change without notifi cation. © 2010 Parker-Hannifi n Corporation
For User Responsibility Statement, see www.parker.com/safety domnick hunter Process Filtration - North America
All Rights Reserved
Fulfl o is a registered trademark of Parker-Hannifi n Corporation
DS_IP_SWC Rev. B
77