Page 212 - Parker - Polyflex Hose Products (Ultra High Pressure Thermoplastic Hose)
P. 212

polyflex     ®
                   Catalog 4900
                   Technical Information                             Installation Tips

                                                          right

                                                                                               wrong





                            wrong

                                                                                              right





                   Hose is weakened when installed in twisted position. Also,  Hose should exit coupling in a straight position rather than
                   pressure pulses in twisted hose tends to fatigue wire and  side loaded. Ample bend radius should be provided to avoid
                   loosen fitting connections. Design so that machine motion  collapsing of hose and flow restriction. Exceeding minimum
                   produces bending rather than torsion.                bend radius will greatly reduce hose assembly life.






                      wrong


                                                                                                                           F
                                                                                                              right
                                                       right




                                                                                  wrong

                   When hose assembly is installed in a flexing application,  Use elbows or other adapters as necessary to eliminate
                   remember that metal hose fittings are not part of the flexible  excess hose length and to ensure neater installation for
                   portion. Allow ample free length for flexing.        easier maintenance.





                                             right



                                                                                                                wrong




                                            wrong

                                                                                                                 right

                   Pressure can change hose length as much as ±3%. Provide  Avoid installing hose line close to exhaust manifold or any
                   slack in line to compensate for hose length changes.  other hot section. If possible, isolate hose with fireproof
                                                                        boot or other protective means.