Page 20 - Parker - Vane pumps single, double, triple T6 mobile application
P. 20
ORDERING CODE - T6DC* SERIES MOBILE APPLICATION
Model No. T6DC* W - B38 - B22 - 1 R 00 - C 1
Series M = Mobile 1 shaft seal Modification
Series P = Mobile 2 shaft seals P1 P2
Seal class
Use for severe duty shaft only* 1 = S1 (for mineral oil)
4 = S4 (for the resistant fluids)
Cam ring for "P1" 5 = S5 (for mineral oil and fire
(Delivery at 0 PSI & 1200 r.p.m.)
B14 = 15.09 GPM B35 = 35.19 GPM resistant fluids)
B17 = 18.45 GPM B38 = 38.14 GPM Design letter
B20 = 20.93 GPM B42 = 43.12 GPM Porting combination (see page 34)
B24 = 25.20 GPM B45 = 46.19 GPM
B28 = 28.44 GPM B50 = 50.09 GPM 00 = standard
B31 = 31.16 GPM Direct. of rotation (view on shaft end)
Cam ring for "P2" R = clockwise
(Delivery at 0 PSI & 1200 r.p.m.) L = counter-clockwise
B03 = 3.42 GPM B17 = 18.48 GPM Type of shaft
B05 = 5.45 GPM B20 = 20.23 GPM Type of shaft M version
B06 = 6.76 GPM B22 = 22.28 GPM P version 1 = keyed (SAE C)
B08 = 8.36 GPM B25 = 25.14 GPM 3 = splined (no SAE) 2 = keyed (no SAE)
B10 = 10.81 GPM B28 = 27.90 GPM 3 = splined (SAE C)
B12 = 11.76 GPM B31 = 31.70 GPM 4 = splined (no SAE)
B14 = 14.58 GPM MW severe duty
*5 = keyed (no SAE)
*T = splined (SAE J718c)
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)
T6DCM - B38 - B22
Internal leakage Qs [GPM] Lp. Noise level [db(A)] 1m ISO 4412
Pressure p [PSI] Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or Double pump noise level is given with each section
viscosity if internal leakage is more than 50% of theoretical flow. discharging at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
Power loss Ps [HP] Load F [Lbs]
Pressure p [PSI] Speed n [RPM]
Total hydrodynamic power loss is the sum of each section at its Maximum permissible axial load Fa = 270 Lbs
operating conditions.
20 Back To The Table Of Content Parker Hannifin
Denison Vane Pump Division
Vierzon - France