Page 14 - Parker - Hydraulic Cartidge System
P. 14
Catalog HY15-3502CPC/US
Technical Information Flow Control Valves
CV
Priority Flow Control (Adjustable)
Dimensions Millimeters (Inches)
4 AF Hex socket Rotate adjuster CW
Valves
Check
SH 24.7 5 AF Hex socket 16.00 to decrease priority (1) (3)
(0.97) max
flow or CCW to
Rotate adjuster CW (0.63) max increase priority flow.
to decrease priority
flow or CCW to
increase priority flow. 13 AF Hex.
10 Nm (7 lb. ft.)
17 AF Hex. 24.00 Torque (2)
Shuttle
Valves
LM 12 Nm (9 lb. ft.) (0.94)
24 Torque 35 AF Hex.
(0.94) 85 Nm (63 lb. ft.)
26 AF Hex. Torque
50 Nm (37 lb. ft.)
Torque 1-3/16" - 12 UNF
Controls
Load/Motor
FC 7/8" - 14 UNF (3)
(3) 74.00
47.3 (2.91)
(1.86)
Controls
Flow
PC (2) (2)
J04D3 J1A125
(1) (1)
Pressure
Controls
LE
Max Inlet Flow Adjustment
Model Body Pressure Rating Range Notes
(PSI) (GPM) (GPM)
J04D3ZN B10-2-8T 6000 12 0.5 to 12
Logic
Elements
DC
J1A125ZN LB10066S* 6000 24 0.5 to 24 3A Cavity
* Not a part of the Core Products 10 Day Lead Time. Consult Factory for Standard Lead Time.
Flow Divider/Combiner
Controls
Directional
MV Dimensions Millimeters (Inches)
8.0
(0.32) Divider Outlets
Combiner Inlets
26 AF Hex. (2) (4)
50 Nm
Manual
Valves
SV (37 lb. ft.)
Torque
(4) 7/8" - 14 UNF
(3)
Divider Inlet
Valves
Solenoid
Combiner Outlet
PV 65
(2.56) (3)
(2)
Valves
Proportional
CE
L04A3
(1)
Max Inlet Flow Adjustment
Electronics
Coils &
BC Model Body Pressure Rating Range
(PSI) (GPM) (GPM)
L04A3-30-30N B10-4-8T 6000 16 3.7 to 15.9
Bodies &
Cavities
12 Parker Hannifin Corporation
Hydraulic Cartridge Systems