Page 64 - Parker - Bodies and Cavities
P. 64
Catalog HY15-3502/US Special Bodies and Cavities
Technical Information 3Z, 3-Way
CV
For additional information see Technical Tips on pages BC1-BC6.
Dimensions Check Valves
Millimeters (Inches)
32.90 (1.295) nom
Valve Length SH
+0.15 Ø 0.05
R = 0.10 –0.00 17.50 max (0.002) A
+0.006 (0.689)
(0.004) –0.000 7.50 min B
(0.295) Shuttle Valves
Ø 0.10
Ø 0.10 (0.004) B
(0.004) A LM
Ø 5.50 max A
Ø 11.60 min (2) (0.217)
(0.457)
R 63 Load/Motor
63 Controls
+0.30 +0.30 FC
G 1/4" (3) (1) Ø 8.75 –0.00 Ø 10.75 –0.00
+0.012
+0.012
(0.344) –0.000 (0.423) –0.000
Flow Controls
R 0.30 max
(0.012)
63 60°
1.00 max PC
0.70 (0.039) +0.05
(0.028) 5.90 Ø 9.00 –0.00
+0.002
(0.232) (0.354) –0.000 +0.05
17.40 max Ø 11.00 –0.00 Pressure Controls
+0.002
(0.685) (0.433) –0.000
22.35 (0.880)
30°
0.03 LE
(0.001) B
R
63 24.00 (0.945) max
30° Elements
Logic
Cavity 9.00
(0.354)
(3) DC
Directional
33.50 Controls
(1.319)
45.00 63.50 MV
(1.772) (2.50)
(2)
Manual Valves
2 holes
(1) SV
12.50 Ø 6.50 through = =
(0.492) (0.256)
30.00 25.00
(1.181) (0.984) Solenoid Valves
38.00
(1.496)
PV
Ordering Information Proportional Valves
Cavity Tooling For 3Z
LB10 Pilot Drill Ø 8.50 (0.335) CE
Line Port Body Step Drill 8DS31355
Body Size Material Reamer (Alum) 8RM31055A Electronics
Reamer (Steel 8RM31055S Coils &
Code Port Size Code Body Material Counterbore —
313 1/4 BSP A Aluminum Tap 8TP31219 BC
320 1/4 SAE S Steel
Bodies & Cavities
TD
Technical Data
BC62 Parker Hannifin Corporation
Hydraulic Cartridge Systems