Page 59 - Clippard - Pneumatic Modules
P. 59

MODULAR VALVE CIRCUITS





             Bleed Piloted 4-Way Valve                                                        C-1
             Pressure in line 4 pilots valve V2 so that    C-1
             the cylinder is retracted on the valve V-2
                                                                                              S
             and C-1 retracted. When V-1 is actuated,                    V-1
             the pressure is exhausted from 4 faster         8   2      MWV-1                 1
             than the restricted supply at 5 can make it             4                  E    7 8  2 3  E
                                                                                             6  4
             up. The spring then shifts the valve and                                         5
                                                              7  3                      V-2
             C-1 extends.                                     1       5                                  V-1
                                                      V-2      S                       R-441
                                                                     S c                      S C       MWV-1
                                                     R-441
             Unique Open-Close Pulse Circuit
             This pulse circuit can be adapted to a wide variety of uses. It consists of an MAV-3 3-way
             valve and two standard R-341 modular valves, and is being used to open and close a
             collet vice on a milling fixture. Circuit operation: when V-1 is depressed, V-2 gives an
                                                                                  OUTPUT        OUTPUT
             output pulse at “A”. The length of the pulse is predetermined by the needle valve
                                                                                    A             B
             adjustment on V-2.
             When V-1 is released, a pulse occurs at “B”.                               6             6
             This pulse is also determined by the length  A         B
                                                 S                S                        3            3
             of the needle valve on V-3. Thus both
                                                                                    2,8          2,8
             pulses are independently ad-                                                    S            S    V-3
                                                8  1  2         8  1  2            V-2     1            1     R-341
             justable. Note that the R-        7   3   E   Vol.  7  3   E
                                                6  4             6  4             R-341
             341 allows supply to be  V-1        5    V-2         5    V-3
             segregated from the pilot  MAV-3                                                   4            4
                                                     R-341            R-341
             signal which allows for                                         V-1        7             7
                                                                            MAV-3                 Vol.
             different pressures or gases
             to be controlled.        S                                           S
             “Latch” Circuit
                                                                C-1                           C-1
             Actuation of V-1 pilots V-3 and extends C-1. The
                                                                            V-2
             same pressure that extends C-1 also passes through            MAVO-3
                                                                                                            V-2
             V-2 and holds the twin pilot down locking C-1 in                                 S
                                                                                                           MAVO-3
             the out position even though V-1 is released. When
                                                             8   2                 V-1
             V-2 is actuated, breaking the line between port 2 &         5        MAV-3      8  1  2
             5, V-3, and exhausting the pilot, the spring will shift     4              E    7 6  4 3  E      V-1
                                                                                               5
             the valve V-3, causing C-1 to retract.           7 1  3  V-3       S        V-3                 MAV-3
                                                               S   R-431                 R-431

             “Active Or” Circuit
                                                        C-1
                                                                           V-1
             Actuation of any one or all of the input                     MAV-3            V-4              C-1
             signal valves, V-1, V-2, V-3, V-4, will                                       MAV-3
                                                                      S
             cause an active output (an output from a
                                                                           V-2
             separate air supply source).                                 MAV-3          V-3       S
                                                     2         4
                                                               5                        MAV-3  S
                                                               7      S
                                              6                8                                  8  1  2
                                                   3    1                  V-3                    7  3    E
                                                                          MAV-3                   6  5  4
                                                       S  V-5                                                  V-1
                                                                                           S
                                                         R-311        S                        V-5            MAV-3
                                                                                               R-311        S
                                                                           V-4
                                                                                                           V-2
                                                                          MAV-3
                                                                                                        S  MAV-3
                                                                      S
         297                                             Clippard Instrument Laboratory, Inc. 877-245-6247 www.clippard.com
   54   55   56   57   58   59   60   61   62   63