Page 54 - Parker - Proportional Valves
P. 54
Catalog HY15-3502/US Proportional Flow Regulator Valve
Technical Information Series DFA125C31
CV
General Description
3 Way, Normally Closed, Proportional Flow Regulator
Valve. Pressure Compensated. For additional informa-
Check
Valves
SH tion see Technical Tips on pages PV1-PV6.
Features
• Analog proportional pressure compensated flow control
valve regulates flow proportionally to the input solenoid
Shuttle
Valves
LM current
• One piece cartridge housing ensures internal
concentricity
(3) Reg.
• Coil: Waterproof, hermetically sealed, requires no (4)
Load/Motor
Controls
FC O’Rings; Symmetrical coil can be reversed without Inlet
affecting performance. (1) (3)
* Bypass *
(2)
(4) (2)
Flow
Controls
*Always connect Port (1) to
PC Port (4) through .039" orifice. Not Used
(1)
Performance Curves
PWM Current Regulator Recommended
Specifications
Pressure
Controls
Pressure Compensation of Regulated Flow (Port 4)
LE
GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Rated Inlet Flow 75 LPM (20 GPM)
20 76.0
15 57.0
Rated Regulated 56.8 LPM (15 GPM)
Flow Requires (‘SP’ Coil) 12 45.6
Elements
Logic
DC
Maximum Input 210 Bar (3000 PSI) Flow 9 34.2
Pressure At Port 3 6 22.8
3 11.4
Minimum Pressure 13.8 Bar (200 PSI) By-Pass Load Higher Regulated Load Higher
Directional
Controls
MV Differential 0 Than Regulated Than By-Pass
Bar 210 140 70 0 70 140 210
PSI 3000 2000 1000 0 1000 2000 3000
Maximum Internal 568 cc (35 cu. in.) Pressure
Leakage @ 210 Bar (3000 PSI)
Regulated Flow vs. Input Current Stabilized
Manual
Valves
SV Hysteresis @ >15% GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)
20 76.0
100 Hz PWM
15 57.0
Cartridge Material All parts steel. All operating 12 45.6
parts hardened steel. Flow 9 34.2
Valves
Solenoid
PV
6 22.8
Operating Temp. -40°C to +93.3°C (Nitrile)
3 11.4
Range/Seals (-40°F to +200°F)
0
-31.7°C to +121.1°C (Fluorocarbon) 25 50 75
(-25°F to +250°F) 0
Proportional
Valves
CE Input Current (%)
Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities Pressure Drop vs. Flow (Through cartridge only)
Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
300 20.7
Electronics
Coils &
BC Filtration ISO Code 16/13,
Pressure
SAE Class 4 or better 200 13.9
Approx. Weight .45 kg (1.0 lbs.) 100 6.9
Cavities
Bodies &
TD Cavity C12-4L 0
(See BC Section for more details) LPM 15.2 30.4 45.5 60.8
0
GPM 4 8 12 16
Flow (Q)
Technical
Data
PV53 Parker Hannifin Corporation
Hydraulic Cartridge Systems