Self-Assembly of Individual Female Plugs Intended Use
Using modular female plugs from the X-COM S-SYSTEM, According to EN 61984, connectors without current inter-
®
female plugs can be customized for applications requiring rupting capacity shall not be mated and unmated when
varying numbers of poles (e.g., when designing proto- live or under load.
types).
Assembly
Modules and Pole Numbers The appropriate mounting tool shall be used to guarantee
A self-assembled female plug consists of: that the individual modules are properly attached to each
Base module with integrated end plate other without damaging the locking latches. 2
up to 13 center modules (corresponding to a 15-pole
female plug = maximum number of poles)
end module.
1 Conductor sizes: 0.25 mm² – 4 mm² “s + f-st”;
Push-in conductor sizes: 0.75 mm² – 4 mm² “s”
and 0.75 mm² – 2.5 mm²
“insulated ferrule, 12 mm”
2 690 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(see Section 14)
3 Current-carrying capacity curves upon request
4 Strip length, see packaging or instructions.
End Module Center Module Base Module
Example: 5-Pole, 1-Conductor Female Plug
Base module with integrated end plate
2022-167
Center module
2022-174
Center modules
2022-171
End module
2022-181