Accessories for Multilevel Installation Terminal Blocks                                              S
                                                                                                                    3

                                                                                                                    159
                                                                                








                                                                                1 Conductor sizes: 0.5 mm² – 6 mm² “s + f-st”;
                                                                                  Push-in conductor sizes: 1 mm² – 6 mm² “s”
                                                                                  and 0.75 mm² – 4 mm²
                                                                                  “insulated ferrules, 12 mm”
                                                                                2 250 V/                            3
                                                                                  400 V  = rated voltage
                                                                                   4 kV/
                                                                                    6 kV = rated surge voltage
                                                                                      3 = pollution degree
                                                                                  (see Section 14)
                                                                                3 250 V/4 kV potential-ground
                                                                                4 400 V/6 kV potential-potential
                                                                                5 Strip length, see packaging or instructions.
          Accessories                                                           Application note:

                          Appropriate marking systems: WMB/Marking strips       N-disconnect slide links, used in installation terminal
                                      (see Section 13)                          blocks, consist of switch contacts that are opened and then
                                                                                closed again as part of the regular circuit testing. To guar-
          Push-in type jumper bar, insulated,    TOPJOB S group marker carrier,   antee a reliable connection, a corrosion-resistant contact
                                                   ®
                    I N 32 A,                          snap-on type for jumper slot,   area is required on the N-busbar.

                    light gray                         5 mm wide                Historically, uninsulated copper busbars, that have been
                    from 1 to 3  2004-433  200  (8x25)  gray    2009-191  50  (2x25)  cleaned/stripped of any possible corrosion prior to install,
                    from 1 to 4  2004-434  200  (8x25)  Screwless end stop,     can be used in dry, pollution-free locations.
                    from 1 to 5  2004-435  100  (4x25)  for DIN 35 rail,          According to DIN VDE 0100-520 (VDE 0100 Part 520),
                    from 1 to 6  2004-436  100  (4x25)  6 mm wide               installation equipment exposed to contamination or corro-
                    from 1 to 7  2004-437  100  (4x25)  gray    249-116  100  (4x25)  sive substances (e.g., water) that promote corrosion or
                    from 1 to 8  2004-438  100  (4x25)  Screwless end stop,     deterioration, must be protected or made of a corrosion-
                                                                                or wear- resistant material. In these cases, tinned copper
                    from 1 to 9  2004-439  100  (4x25)  for DIN 35 rail,        busbars guarantee a reliable connection.
                    from 1 to 10  2004-440  100  (4x25)  10 mm wide
                                                       gray     249-117  50  (2x25)  WAGO only offers tinned copper busbars.
          Push-in type wire jumper,          Operating tool,
                    insulated,                         3.5 mm and 5.5 mm blade,
                    I N 18 A,                          for TOPJOB S installation terminal blocks
                                                              ®
                    wire size 1.5 mm²                        2009-310        50
                    L = 60 mm  2009-412 100  (10x10)  Operating tool,
                    L = 110 mm  2009-414 100  (10x10)  3.5 mm and 2.5 mm blade,
                    L = 250 mm  2009-416 100  (10x10)  for TOPJOB S installation terminal blocks
                                                              ®
                                                             2009-309        50
          Test plug adapter,
                    for 4 mm Ø test plug
                    gray     2009-174  100  (4x25)
          Banana plug,
                    for socket 4 mm Ø,
                    color mixed
                             215-111      50
          Testing tap,
                    for max. 2.5 mm²
                    gray     2009-182  100  (4x25)
          Test plug,
                    with 500 mm cable,
                    2 mm Ø
                    red      210-136      50
          Test plug,
                    with 500 mm cable,
                    2.3 mm Ø
                    yellow   210-137      50
          WMB Multi marking system,
                    10 strips with 10 markers per card,
                    stretchable 5 - 5.2 mm
                    plain    793-5501      5
          Marking strip, plain,
                    11 mm wide,
                    50 m roll
                    white    2009-110      1